Technical Specifications
www.simerpump.com • 1-800-468-7867
• Superior performance at depths to water of 20' or less
•
Fiberglass reinforced thermoplastic pump housing for the
highest corrosion resistance
• Ready to install 230 volt, heavy-duty motor, see manual
for 115 volt conversion
• Self priming after pump housing is initially lled,
protects against overheating
SPRINKLER
PUMP
MODEL 3420P 2 HP
MODEL 3415P 1-1/2 HP
MODEL 3410P 1 HP
Model UPC Carton (L x W x H) Cube Pallet Qty. Weight
3420P 0 22315 31584 6 21.563" x 12.813" x 15.375" 2.458
18 41.2 lbs.
3415P 0 17561 91169 0 21.563" x 12.813" x 15.375" 2.458 18 35.0 lbs.
3410P 0 22315 31583 9 21.563" x 12.813" x 15.375" 2.458 18 30.6 lbs.
Motor NPT Pipe Size Distance of Pump Discharge Pressure PSI
Model HP Warranty Voltage Suction Discharge Above Water 10 15 20 25 30 35 40 45 50
3420P 2 1-year 115/230
2" 2" 5 ft. 69 64 59 53 47 40 34 24 14
10 ft. 67 62 56 50 45 38 30 18 7
15 ft. 65 60 54 48 42 35 27 13 –
20 ft. 62 57 52 46 40 32 23 10 –
3415P 1-1/2 1-year 115/230 1-1/2" 1-1/2" 5 ft. 67 66 61 55 48 39 33 18 –
10 ft. 61 58 56 52 45 37 27 14 –
15 ft. 56 55 54 51 44 35 20 8 –
20 ft. 46 45 44 43 37 28 11 – –
3410P 1 1-year 115/230 1-1/2" 1-1/2" 5 ft. 55 51 45 38 31 23 17 – –
10 ft. 49 46 42 35 28 19 13 – –
15 ft. 48 45 39 32 24 16 8 – –
20 ft. 45 44 37 29 20 11 – – –
ORDERING INFORMATION
PERFORMANCE
1
YEAR
WARRANTY
SPRINKLER PUMPS
MODELS 3420P, 3415P, 3410P
63