PRE-CHARGE TANK CONNECTION
(FIGURE 4)
1. Install two tees in the pump discharge port (see
Figure 4). The pipe size must be at least as large as
the discharge port.
2. Run a pipe or reinforced hose from one arm of the
first tee to the port on the pre-charged tank.
3. Connect the other end of the discharge tee to your
plumbing system.
4. Check the pre-charge of air in the tank with an ordi-
nary tire gauge. The pre-charge should be 2 PSI less
than the cut-in setting of the pump’s pressure switch.
The pre-charge is measured when there is no water
pressure in the tank. Your new pump has a 30/50 PSI
switch, so adjust the tank pre-charge pressure to 28
PSI.
Congratulations! You have just completed the tank
connection for your jet pump.
STANDARD TANK CONNECTION
(FIGURE 5)
1. Install one tee in the pump discharge port (see Figure
5).
2. Run a pipe from the pump discharge port to the inlet
port of your tank. The pipe size must be at least as
large as the discharge port.
3. Remove the 1/8” NPT pipe plug from the pump Air
Volume Control (AVC) port (see Figure 5). Run tubing
from the pump’s AVC port (see Figure 5) to the port
on the AVC mounted on the tank. See instructions
provided with tank and AVC for details. AVC port
location will vary, depending on your pump model
(see exploded views, Page 10).
Sealing Pipe Joints
Use only Teflon tape for making all threaded
connections to the pump itself. Do not use pipe
joint compounds on plastic pumps: they can
react with the plastic in pump components.
Make sure that all pipe joints in the suction pipe
are air tight as well as water tight. If the suction
pipe can suck air, the pump will not be able to
pull water from the well.
Pressure Switch
Not
to
Scale
Check
Valve
Suction Pipe
From Well
Pump Priming
Tee and Plug
To Household
Water System
Figure 4 – Pre-charged Tank Connections
To Household
Water System
From
Well
Air Volume
Control
Air Volume
Control Tube
Pump
Priming Tee
and Plug
Not
to
Scale
Pressure
Switch
Pump AVC Port
Figure 5 – Standard Tank Connections