SDS

Biological limit values
ACGIH Biological Exposure Indices
Value
Sampling TimeDeterminant SpecimenComponents
0.15 g/g Sum of
mandelic acid
and
phenylglyoxylic
acid
Creatinine
in urine
*
Ethylbenzene (CAS
100-41-4)
1.5 g/g Methylhippuric
acids
Creatinine
in urine
*
Xylene (CAS 1330-20-7)
* - For sampling details, please see the source document.
Explosion-proof general and local exhaust ventilation. Good general ventilation (typically 10 air
changes per hour) should be used. Ventilation rates should be matched to conditions. If
applicable, use process enclosures, local exhaust ventilation, or other engineering controls to
maintain airborne levels below recommended exposure limits. If exposure limits have not been
established, maintain airborne levels to an acceptable level.
Appropriate engineering
controls
Individual protection measures, such as personal protective equipment
Chemical respirator with organic vapor cartridge and full facepiece.
Eye/face protection
Skin protection
Wear appropriate chemical resistant gloves. Suitable gloves can be recommended by the glove
supplier.
Hand protection
Skin protection
Wear appropriate chemical resistant clothing. Wash hands thoroughly after handling. Use of an
impervious apron is recommended.
Other
Chemical respirator with organic vapor cartridge and full facepiece.
Respiratory protection
Wear appropriate thermal protective clothing, when necessary.
Thermal hazards
When using do not smoke. Always observe good personal hygiene measures, such as washing
after handling the material and before eating, drinking, and/or smoking. Routinely wash work
clothing and protective equipment to remove contaminants. Contaminated work clothing should not
be allowed out of the workplace.
General hygiene
considerations
9. Physical and chemical properties
Appearance
Liquid.
Physical state
Liquid.
Form
Transparent Blue.
Color
Characteristic odor.
Odor
Odor threshold
Not available.
pH
(Not applicable; suspension)
Melting point/freezing point
Not determined.
Initial boiling point and boiling
range
Not available.
Flash point
107.6 °F (42.0 °C) Pensky-Martens Closed Cup
Evaporation rate
< 1 (n-Butyl acetate = 1)
Not applicable.
Flammability (solid, gas)
Upper/lower flammability or explosive limits
Flammability limit - lower
(%)
Not available.
Flammability limit - upper
(%)
Not available.
Explosive limit - lower (%)
Not available.
Explosive limit - upper (%)
Not available.
Vapor pressure
Not determined.
Vapor density
> 1 (at 25 °C) (Air = 1)
Relative density
1.13 (at 25 °C)
SDS US
4 / 9
TEKTOP TPO PRIMER