SDS

Page 4 of 7
Respiratory protection
For nuisance exposures use type P95 (US) or type P1 (EU EN 143) particle respirator.For higher level
protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges. Use respirators and
components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Control of environmental exposure
Do not let product enter drains.
9. PHYSICAL AND CHEMICAL PROPERTIES
9.1 Information on basic physical and chemical properties
a)
Appearance
Form: crystalline
Colour: white
b)
Odour
No data available
c)
Odour Threshold
No data available
d)
pH
1.8 at ca.50 g/l at 25 °C (77 °F)
e)
Melting point/freezing
point
Melting point/range: 153 - 159 °C (307 - 318 °F) - lit.
f)
Initial boiling point and
boiling range
No data available
g)
Flash point
No data available
h)
Evaporation rate
No data available
i)
Flammability (solid, gas)
No data available
j)
Upper/lower
flammability or
explosive limits
Lower explosion limit: 8 %(V)
k)
Vapour pressure
No data available
l)
Vapour density
No data available
m)
Relative density
No data available
n)
Water solubility
383 g/l at 25 °C (77 °F)
o)
Partition coefficient: n-
octanol/water
log Pow: -1.639 at 20 °C (68 °F)
p)
Auto-ignition
temperature
No data available
q)
Decomposition
temperature
No data available
r)
Viscosity
No data available
s)
Explosive properties
No data available
t)
Oxidizing properties
No data available
9.2 Other safety information
No data available
10. STABILITY AND REACTIVITY
10.1 Reactivity
No data available
10.2 Chemical stability
Stable under recommended storage conditions.
10.3 Possibility of hazardous reactions
No data available