4.2.3.5 RSSI
1. Select the RSSI Cal page.
2. Set the Signal Generator for a RF output level of -90dBm and 2kHz deviation at the specified
frequency.
3. Activate the Store RSSI button.
The receiver RSSI threshold setting is calibrated.