4.1.17
RSSI Calibration
Calibration procedure
1
Select the
RSSI Cal
page.
2 Set the Signal Generator for a RF output level of -90dBm and 3kHz deviation at the specified
frequency.
3
Activate the
Store RSSI
button.
The receiver RSSI threshold setting is calibrated.