Unit installation
Manual – Digital Half Cylinder 3061 
Page 8 
3.2 Time zone control 
This is only possible with the .ZK version. It is possible to load time zones which then 
authorise and block transponders according to their time zone group. 
A time zone plan also enables time-controlled switching. 
3.3 Overlay Modus 
This mode applies to the complete locking system and needs to be selected during the 
system's design phase. Replacement transponders can overwrite the original trans-
ponders. The first use of a replacement transponder will overwrite and block the origi-
nal transponder. 
3.4 Extended activation 
The half cylinder engages the knob for approx. 5 seconds as standard. The 
software allows the time to be extended to 10 seconds. This does not
 shorten 
the battery life. 
3.5 OMRON 
Every product version is operable in OMRON mode. You should select this option for 
both the Smart Relay and the cylinder if you want the Smart Relay to transmit trans-
ponder data to a different system and subsequently send a remote opening command 
to a half cylinder on approval by the other system. 
Attention:
 Cylinders using this configuration cannot be opened by a transponder. 
Please refer to the "Smart Relay" manual for a detailed description. 
3.6 Warehouse mode 
Half cylinders are delivered in warehouse mode to preserve battery power. Half cylin-
ders in warehouse mode cannot be addressed by a transponder. The warehouse mode 
is deactivated when the half cylinder is programmed for the first time. It is also possible 
to deactivate the warehouse mode using the programming software without creating a 
locking plan. 
For warehouse mode after battery warning level 2: see chapter 6. 
3.7  No acoustic programming confirmation 
This checkbox should be activated if you want to suppress the acoustic con-
firmation signal for programming or reading data from the half cylinder. 