Unit installation
Smart Relay: SREL, SREL.ZK, SREL.ADV 
Page 19 
+ / ~
- / ~
NC
COM
NO
Brown
White
Green
Grey
Yellow
Batterie SREL.BAT
Netzteil
{
Relais
{
}
Externe Antenne
SREL.AV
1 K 1 K
GND
+ 5..12VDC
Clock
Data
Externes Zutrittskontroll- oder
Zeiterfassungssystem
F2 F1
Pull Up Widerstände
CLS
1 K
Pull-up resistors 
External antenna 
SREL.AV
Power supply 
Battery SREL.BAT 
Relay
External access control or time 
recording system
8.3  Kaba Benzing, Siemens, Gantner Legic, Primion, Isgus Interface 
9.0 Maintenance 
9.1  Battery Warning and Battery Replacement if you are using the 
SREL.BAT battery 
In case the battery capacity is no longer sufficient, a Smart Relay can issue a battery 
warning as follows: 
SREL, SREL.ZK, SREL.ADV 
  Internal LED blinks 8 times each time you operate the transponder and before 
the relay is switched.  
If you are operating with a battery, you should make sure that this LED can be 
seen from the outside.   
Only SREL.ADV 
  External LED blinks 8 times or external buzzer beeps 8 times, each time you 
operate the transponder. 
Approximately 100 operations are possible after the battery warning, so you 
should replace the battery as soon as possible. 