Unit installation
Smart Output Module 
Page 14 
8.4  Adjust the Pulse Length 
The modules appear in the locking plan as the locking type "expansion module". You 
can select a pulse length from 0.1 to 25.5 seconds in the configuration for each 
module. This length then applies to all of the module's outputs. 
8.5 Select Signaling 
Signaling is a special function where two of a module's outputs always work together. 
The first output reacts completely normally, depending on transponder operation; the 
output assigned to it simultaneously generates an alternating signal. You can select 
this option, for example, if you want to have the keys that are released when an 
elevator is controlled blink. 
Attention: If you select this option, the number of outputs that are switched 
when authorized is reduced from eight to four. 
Output assignments for signaling: 
1 Æ 5 
2 Æ 6 
3 Æ 7 
4 Æ 8 
8.6  Automatic Name Assignment in the Software 
The SimonsVoss software automatically assigns designation to modules when the 
modules are created. The following convention is used: 
SMART RELAY NAME       - MOD0 - OUT1 
(z.B. Aufzug1-MOD0-OUT4) 
8.7  Inverting the Outputs 
This option allows the output switching behavior to be inverted. If there is no supply 
voltage, all output relays are always closed. 
Module 
address: 
0 to F 
Output 
number: 
1 to 8 