Unit installation
VdS Shunt lock function 3066 
Page 22 
3.2  Programming the Deactivation Units (DA) 
Click the line in the locking plan above the one where you want to add a deactivation 
unit. Select 
New  Locking. Then give the deactivation unit a name: 
  Such as Deactivation unit, main entrance 
In the field 
Type, select Control unit. Click OK & Exit. If you want to set up additional 
deactivation units, repeat these steps. 
☺  If you always add the deactivation units above the accompanying digital 
locking cylinder, you will have a better overview of the system. 
Deactivation units do not need any authorizations which means that you do not have 
to insert any crosses. Approve your locking system and program the deactivation 
units under 
Programming  Locking. 
  The deactivation unit needs supply voltage during the programming. You can 
provide this with a 9-volt compound battery, for example. Program activation 
unit(s) and deactivation units separately from one another. Do not wire the two 
components until after you have programmed them successfully. 










