Unit installation
WAVENET RADIO NETWORK 3065 
Page 21 
7.9 LockNodes 
WaveNet LockNodes represent the interface between WaveNet and the locks in the 
digital locking and organisation system 3060 (e.g. locking cylinders, Smart Relays 
etc.). 
They always have: 
•  a special B-field interface which enables communication with SimonsVoss locks 
(e.g. locking cylinders, control units/Smart Relays, furniture locks, etc.) 
•  a radio interface (868 MHz) to ensure data transmission to the WaveNet nodes 
(e.g. WaveNet router nodes, WaveNet repeater nodes or WaveNet central 
nodes) or 
•  an RS485 interface and connection for an external power supply, for operation in 
a ‘wired WaveNet’ (WN.LN.C) 
WaveNet LockNodes can always be assigned to just one digital lock in the system 
(e.g. a locking cylinder, Smart Relay or furniture lock, etc.). The distance between the 
WaveNet LockNode and a digital cylinder / furniture lock must be no more than 30 
cm. A minimum distance of 40 cm must be maintained between the LockNode and a 
Smart Relay. We recommend fitting a cable connection between both components 
with  WN.KAB.WIRED-BF. In this scenario, no minimum gap needs to be observed 
(with SREL.ADV only). 
In a radio network, WaveNet LockNodes are battery-operated and can therefore be 
integrated in the SimonsVoss WaveNet with no wiring whatsoever. This makes the 
system ideal for later installation in an existing building. 
The wired variant of the LockNode (WN.LN.C) features connections for the RS485 
bus and for the external power supply. 
(see 7.9). 
To simplify installation as far as possible, the housing of the WaveNet LockNode is 
designed to be installed in a standard built-in mounting box (60 mm deep,  
55 mm in diameter) in accordance with DIN  49073 Part 1 (e.g. for installation in a 
light switch panel). 
Lock Node 
with housing