Unit installation
WAVENET RADIO NETWORK 3065 
Page 27 
10.0 BATTERY WARNING. 
If the voltage of the batteries fitted in the LockNode falls below a certain level, 
communication problems may arise both between the LockNode and the associated 
lock and between the LockNode and a router node (WaveNet router node, WaveNet 
central node). 
If any such problems arise, the ‘N’ after the relevant lock will be shown in red 
(indicating communication fault). If the red ‘N’ does not turn yellow or blue even after 
repeating the protocol, check whether the battery needs to be replaced. 
11.0   NETWORK ‘N’ / ‘W’. 
In the LDB/LSM, locks/doors are labelled with an ‘N’ / ’W’ if they are fitted with a 
LockNode. ‘N’s’ / ‘W’s’ are shown in the following colours to differentiate between 
statuses. 
Red ‘N’/’W’:  No connection to LockNode. 
Yellow ‘N’/’W’:  Connection to LockNode but not
 to lock (door may be open) 
Blue ‘N’/’W’:  Connection to LockNode and
 to lock 
12.0 REPLACING LOCKNODE BATTERIES. 
To replace the batteries in the LockNode, you need to remove the LockNode from its 
installation position (e.g. built-in mounting box) and unscrew the cover on the back. 
The position of the two batteries is clearly labelled in the battery compartment. Only 
use batteries which have been approved by SimonsVoss. 
When inserting the new batteries, please observe the LED. Immediately after you 
insert the first
 new battery in the empty battery compartment, the LED must flash 
briefly twice. The node is then ready for operation (power-on reset). If the LED does 
not light up, please take the battery out again, short-circuit the battery contacts of the 
LN and re-insert the battery. 