Unit installation
LON – Network 3065 
Page 11 
Connect the network cable to terminals 1 and 2 
of the LockNode.  If you need an antenna 
extender because of a double door, connect the 
antenna extender cable to the terminals, 
according to the line colours. 
When connecting the extended antenna, also remove the four solder bridges (0Ω 
resistors) on the LockNode printed circuit board. Otherwise, the LockNode cannot 
function with the extended antenna. 
    Solder bridges (closed) 
To open the solder bridges, please use an appropriate tool (adjustable soldering iron 
and unsoldering suction pump). 
  Only authorised personnel should install and open the solder bridges. 