Unit installation
Programming Transponder 3067 
Page 4 
3.0 Programming Notes 
Always position only one locking cylinder in the immediate vicinity of the 
Programming Transponder during programming. All other components must be at a 
distance of at least 1 m (3.3 feet). 
3.1 Error Messages 
If you receive one of the following signals when not expected during the 
programming, there has been an error. 
z  Light emitting diode (LED) blinks red 1x:   
Action: Correct the distance to the cylinder or transponder and try again. 
z  LED flickers and then blinks red 2x.   
You have tried to authorise a transponder in more than 3 different locking 
systems. (A transponder can be authorised for a maximum of 3 different 
locking systems). 
z  LED flickers and then blinks red 3x:   
You have tried to program more than the maximum allowable number of 
transponders or cylinders. 
z  LED flickers and then blinks red 4x.   
You have tried to authorise a transponder for a cylinder that does not 
belong to your locking system.   
or 
The programming transponder button was pressed too long. 
3.2 Initial Programming 
The following programming steps must be done very quickly, because otherwise 
the Programming Transponder automatically shuts down, which interrupts the 
programming. 
Be absolutely sure to maintain a minimum distance of 1 meter (3.3 feet) from the 
locking cylinder to the Programming Transponder when carrying out steps 1 and 2. 
1.  Briefly press the Programming Transponder button once. The light emitting 
diode then blinks green. 
2.  Operate the transponder that you want to program at a distance of from 
approximately 10 to 20 cm (4 to 8 in.) to the Programming Transponder and 
wait until the light emitting diode on the Programming Transponder lights 
green for three seconds. If you want to authorise another transponder, repeat 
step 2. 
3. Once you have authorised all transponders, hold the Programming 
Transponder near the inner knob of the cylinder (long knob) and briefly press 










