Technical data
SMART RELAY SREL, SREL.ZK, SREL.ADV 
15
7.7.2  NO AUDIBLE PROGRAMMING ACKNOWLEDGEMENT SIGNALS 
SREL.ADV only 
You should check this field if you do not want audible programming acknowledgement 
signals to be emitted from a connected buzzer or beeper while you are programming 
Smart Relay. 
7.7.3  EXTERNAL LED / EXTERNAL BEEPER 
SREL.ADV only 
This indicates which external component group is connected. In flip flop mode, Smart 
Relay emits a permanent signal when switched on if there is an external LED; in the 
case of a beeper, an audible signal is only emitted when there is a change of status. 
7.7.4 INTERNAL/EXTERNAL ANTENNAS 
SREL.ADV only 
- Auto-detection 
If an external antenna is connected, this is the one which is used. Smart Relay 
switches off the internal antenna in such cases. If no external antenna is con-
nected (standard case), Smart Relay functions with the internal antenna. 
- Both active 
Smart Relay is able to use both antennas to verify transponder bookings. 
7.7.5  NUMBER OF EXTENSION MODULES 
This is where you indicate the number of external modules connected to the Smart 
Relay. These modules are connected to the terminals RS-485 COM, RS-485 A and 
RS-485 B. You will find more detailed information in the documentation for individual 
modules. 
7.7.6 PULSE LENGTH 
This is where you indicate the number of seconds for the switch pulse duration. The 
value can be set at 0.1 to 25.5 seconds. If you enter 3 seconds, for example, an elec-
tric strike is released for 3 seconds before it locks again. 










