Specifications

Section 4: Telephones and Optional Equipment
4-40 Section 4: Telephones and Optional Equipment Aspire S Hardware Manual
10. Using the ferrite bead that was included with the APA/APR
Adapter, wrap the line cord once through the ferrite bead and snap
it shut.
11. Plug the end of the line cord for the analog device which has the
ferrite bead closest to it into the jack on the adapter. The opposite
end should then be connected to the analog device.
To avoid any hardware problems, when removing the adapter, rst unplug the line cord, then
the power cord, then any other adapter cables.
12. To determine the APR’s analog extension number . . .
10-03-04 : Optional Installed Unit 1
Displays the type of terminal installed. This can be used to verify that the system recognizes the
adapter.
10-03-06 : PCB Setup
Assign the terminal type (12) for the keyset’s channel which has the APR Adapter installed.
When you wish to have the APR use the same extension number as the keyset to which it is
attached (like an APA), remove the terminal type in this option. With this setup, when the analog
device is in use, it busies out the keyset as there is no separate port number assigned for the adapter.
To reverse this, and allow the APR to have its own extension number, simply reassign the terminal
type (12) in this option.
10-03-07 : PCB Setup
The port number of the APR Adapter is displayed for the extension (APR ports = 11-26 with all
software through 2.21 OR 11-42 with 2.50 software and higher). The ports are assigned from the
highest available port down.
The APR will be assigned to the rst unused port in descending order, starting from port 26 or
42. If there is no extension port available for the APR, it will function like an APA adapter (either
phone can be used, but only one at a time).
11-02-01 : Extension Numbering
To determine the extension number assigned for the APR device, refer to the table below.
Refer to Section 5: Data and SMDR for additional details.
APR Extension Port Number Extension Number
11 311
12 312
::
25 325
::
26 or 42 *
* Above 26, software 2.50 or
higher is required.
326 or 342 *
* Above 326, software 2.50 or
higher is required.