Datasheet

46 Zeus 2.5-Inch ATA Solid State Drive
Non-Operating Requirements
Note: Non-operating requirements include shipment and storage environments. See Table 15.
Table 15. Non-Operating Requirements
Relative Humidity
Table 16 lists the operating and non-operating relative humidity criteria for the Zeus SSD.
Table 16. Relative Humidity Criteria
Altitude Parameters
Operating and non-operating altitude parameters for the Zeus SSD are the same, with a low-altitude
limit of -1,000 ft. (-304.80m) and a high-altitude limit of 80,000 ft. (24,384m). Altitude is referenced to
sea-level on a standard day at 58.64
o
F (19.8
o
C)
Table 17. Operating and Non-Operating Altitudes
Non-Operating Requirements
Temperature Range
-55
o
C to 95
o
C
Maximum Temperature Gradient
30
o
C/h
Short Duration Temperature
82
o
C for 2h
Relative Humidity Range (Non-condensing)
5% to 95%
Maximum Wet Bulb Temperature
38
o
C
Maximum Relative Humidity Gradient
20%/h
Operating Criteria
Relative Humidity Range (Non-Condensing)
5% to 95%
Maximum Wet Bulb Temperature
29
o
C
Maximum Relative Humidity Gradient
20%/h
Non-Operating Criteria
Relative Humidity Range (Non-Condensing)
5% to 95%
Maximum Wet Bulb Temperature
38
o
C
Maximum Relative Humidity Gradient
20%/h
Altitude Parameter Criteria
Low Altitude Limit
-1,000 ft. (-304.80m)
High Altitude Limit
80,000 ft. (24,384m)