Datasheet

Zeus 2.5-Inch ATA Solid State Drive 59
Radio Frequency Immunity Requirements
This specification is targeted as part of the design for quality and reliability expectations and is not
part of the regulatory requirements. The SSDs meet the following radio frequency immunity
requirements:
3 V/m over frequency range of 80 MHz to 1 GHz
The signal will be amplitude modulated with a 1KHz sine wave to a depth of 80%
Failure criteria: More than 10% throughput degradation
EMI Test Site Correlation
STEC Inc. will only use EMI test sites that are currently correlated with the customer’s test facilities.
STEC Inc. will contact the customer’s engineering staff for the list of approved laboratories.
Verification Samples
STEC Inc. will submit the three worst-case drives used to obtain the emissions test data previously
obtained from the customer’s test facilities for verification testing. The Regulator Engineer will use
these drive samples, and others among those submitted for qualification, for emissions verification in
the customer’s systems.
Verification Testing
Verification testing will be performed by the customer’s Compliance Peripheral Group.