Datasheet

60 Zeus 2.5-Inch ATA Solid State Drive
Electrostatic Discharge (ESD)
The SSD will meet the ESD limits specified in the 61000-4-2 guidelines and the customer’s enhanced
ESD procedure. The specification will determine whether the contact or air discharge method should
be used. Performance degradation is defined as a decreased throughput rate. No data error are
allowed. Table 23 lists the ESD requirements.
Table 23. ESD Requirements
Acceptance Criteria Definitions
The following table lists the acceptance criteria definitions for the ESD limits.
Table 24. Acceptance Criteria Definitions
Climatic Conditions
Ambient Temperature 15
o
C to 35
o
C
Relative Humidity 30% to 60%
Atmospheric Pressure 86kPa (860 mbar) to 106 kPa (1060 mbar
Voltage Level Discharge Type Pass/Fail Performance Criteria
+/-2 kV Contact A
+/-4 kV Contact B
+/- 6 kV Contact B
+/-8 kV Contact C
+/--2 kV Air A
+/-4 kV Air A
+/-8 kV Air B
+/-12 kV Air B
+/-15 kV Air C
A
The apparatus will continue to operate as intended, i.e., normal unit
operation with no degradation of performance.
B
The apparatus will continue to operate as intended after completion of the
test. However, during the test, some degradation of performance is
allowed provided there is no data loss or operator intervention to restore
apparatus function.
C
Temporary loss of function is allowed. Operator intervention is acceptable
to restore apparatus function.
Note: Hardware failures are not acceptable for any level of the above
performance criteria.