Product manual

36 Zeus
IOPS
3.5-Inch Fibre Channel Solid State Drive
TEST UNIT READY COMMAND (00h)
The TEST UNIT READY command provides a method to check if the logical unit is ready. This is
not a request for a self-test. If the logical unit would accept an appropriate medium-access command
without returning CHECK CONDITION status, this command shall return a GOOD status. If the
logical unit cannot become operational or is in a state such that an initiator action is required to make
the unit ready, the target shall return CHECK CONDITION status with a sense key of NOT READY.
Byte 5 is ignored..
F
ORMAT UNIT (04h)
The FORMAT UNIT (04h) command will request that the device server format the medium into
application client-accessible logical blocks as specified in the number of blocks and block length
values received in the last mode parameter block descriptor in a MODE SELECT command. The
device server may certify the medium and create control structures for medium management and
defects. The degree to which the medium is altered is vendor-specific.
Table 14. Format Unit Command
Table 13. Test Unit Ready CDB
Bit
Byte 7 6 5 4 3 2 1 0
0 Operation Code (00h)
1 Reserved Reserved
2 Reserved
3 Reserved
4 Reserved
5 Control
Bit
Byte 7 6 5 4 3 2 1 0
0 Operation Code (04h)
1
FMTPINFO RTO_REQ LONGLIST FMTDATA CMPLIST DEFECT LIST FORMAT
2 Vendor Specific
3
Obsolete
4
5 Control