Specifications
Control Interface Module, Continued
CIM Display/Touch Screen
Removal and Installation
Step Procedure
Note: Although the CIM color display and the touch screen are
separate parts, they are shipped as one assembly attached
to a metal mounting plate. Due to the need for special tools
to correctly align the two devices, the display and touch
screen should NOT be disassembled on-site. This procedure
describes the steps to remove and replace the entire
CIM Display assembly.
1. Because this procedure involves removing the CIM-Board,
save the current Maxum .amd database file before
beginning. Once the database is saved, power off the
Maxum.
2. Open electronic enclosure door (using a 4mm (5/32”) Allen
wrench if necessary).
3. Remove the CIM-Board (combination of CIM-Base and
CAC3) as described previously in the procedure titled,
CIM-Base Removal and Installation.
4. Using a 7 mm nut driver or wrench, remove the six nuts that
secure the display assembly to the door. Note: There are
several nuts on the surface of the metal mounting plate. Only
the 7 mm nuts secure the assembly to the door.
5. Carefully remove the display assembly from the door. In
order to break the seal, it may be necessary to carefully pull
the edges of the display away from the door.
6. Remove the cables from the old display and plug them into
the new display. Note: The display control interface cable
should be secured to the mounting plate using a tie-wrap as
shown below. This must be cut and the cable secured to the
new display using a similar tie-wrap.
4-10 A5E31405710001