Specifications

G10
GE Limitamp
®
Medium Voltage Motor Control
Components
G
Applications
All power generation, transmission, distribution, motor
protection applications
Generator, Differential, Phase, Transformer, Bus, Feeder,
Breaker and Motor protection, monitoring, metering and
control
Utility substation and industrial plant automation
Digital Fault Recorder and Sequence of Event
Predictive maintenance through data analysis and trending
Key Benefits
Application flexibility – multiple I/O options, programmable
logic (FlexLogic
), modularity, customize to specific
requirements
Fewer external devices required – multifunction device that
integrates protection and control functions, programmable
pushbuttons and status LEDS, and communication interfaces
Modular construction – common hardware, reduced stock
of spare parts, plug & play modules for maintenance cost
savings and simplification
Common platform – reduced training time and drafting costs
Use high speed communications to reduce wiring and
installation costs – exchange inputs and outputs between
relays to achieve relay-to-relay interaction
Cost effective and flexible access to information – multiple
communication options and protocols
Reduce system event analyzing time and cost – sequence
of event reports, oscillography, datalogging, IRIG-B time
synchronization
Long lasting life – when exposed to chemically corrosive
and humid environments with optional conformal coating
Enhanced CT/VT Diagnostics – enhanced CT/VT module
diagnostics verifying the integrity of the analog signals
using an advanced algorithm ensuring reliable performance
of the relay
Features
Protection and Control
Extensive protection and control capabilities
Up to 96 digital input and 64 digital outputs
Solid state output modules for fast tripping
Transducer I/Os (RTD, dcmA)
Dual power supply (option)
Communications
Networking options – Ethernet-fiber (optional redundancy),
RS422, RS485, G.703, C37.94
Multiple protocols – IEC 61850, DNP 3.0 Level 2, Modbus
RTU, Modbus TCP/IP, IEC 60870-5-104, Ethernet Global
Data (EGD)
Direct I/O – exchange of binary data between URs
Monitoring and Metering
Synchrophasors
Oscillography – up to 64 records
Event Recorder – 1024 time tagged events, with 0.5ms
scan of digital inputs
DataLogger – up to 16 channels with user selectable
sampling rate
• Fault locator and user programmable fault reports
Breaker condition monitoring including breaker arcing
current (I2t)
Metering – current, voltage, power, power factor, frequency,
current harmonics
User Interface and Programming
Fr
ont panel display and keypad for local access; RS232
port for local PC access
User programmable local display, LEDs and pushbuttons
Customize protection and control functions with
FlexLogic
, FlexCurves
, and FlexElements
Includes EnerVista LaunchPad – Simple relay setup and
programming
Multi-language – French, Chinese, Russian option
Universal Relay
Family