Specifications
G10
GE Limitamp
®
Medium Voltage Motor Control
Components
G
Applications
• All power generation, transmission, distribution, motor
protection applications
• Generator, Differential, Phase, Transformer, Bus, Feeder,
Breaker and Motor protection, monitoring, metering and
control
• Utility substation and industrial plant automation
• Digital Fault Recorder and Sequence of Event
• Predictive maintenance through data analysis and trending
Key Benefits
• Application flexibility – multiple I/O options, programmable
logic (FlexLogic
™
), modularity, customize to specific
requirements
• Fewer external devices required – multifunction device that
integrates protection and control functions, programmable
pushbuttons and status LEDS, and communication interfaces
• Modular construction – common hardware, reduced stock
of spare parts, plug & play modules for maintenance cost
savings and simplification
• Common platform – reduced training time and drafting costs
• Use high speed communications to reduce wiring and
installation costs – exchange inputs and outputs between
relays to achieve relay-to-relay interaction
• Cost effective and flexible access to information – multiple
communication options and protocols
• Reduce system event analyzing time and cost – sequence
of event reports, oscillography, datalogging, IRIG-B time
synchronization
• Long lasting life – when exposed to chemically corrosive
and humid environments with optional conformal coating
• Enhanced CT/VT Diagnostics – enhanced CT/VT module
diagnostics verifying the integrity of the analog signals
using an advanced algorithm ensuring reliable performance
of the relay
Features
Protection and Control
• Extensive protection and control capabilities
• Up to 96 digital input and 64 digital outputs
• Solid state output modules for fast tripping
• Transducer I/Os (RTD, dcmA)
• Dual power supply (option)
Communications
• Networking options – Ethernet-fiber (optional redundancy),
RS422, RS485, G.703, C37.94
• Multiple protocols – IEC 61850, DNP 3.0 Level 2, Modbus
RTU, Modbus TCP/IP, IEC 60870-5-104, Ethernet Global
Data (EGD)
• Direct I/O – exchange of binary data between URs
Monitoring and Metering
• Synchrophasors
• Oscillography – up to 64 records
• Event Recorder – 1024 time tagged events, with 0.5ms
scan of digital inputs
• DataLogger – up to 16 channels with user selectable
sampling rate
• Fault locator and user programmable fault reports
• Breaker condition monitoring including breaker arcing
current (I2t)
• Metering – current, voltage, power, power factor, frequency,
current harmonics
User Interface and Programming
• Fr
ont panel display and keypad for local access; RS232
port for local PC access
• User programmable local display, LEDs and pushbuttons
• Customize protection and control functions with
FlexLogic
™
, FlexCurves
™
, and FlexElements
™
• Includes EnerVista LaunchPad – Simple relay setup and
programming
• Multi-language – French, Chinese, Russian option
Universal Relay
™