G11
GE Limitamp
®
Medium Voltage Motor Control
Components
G
Applications
• Primary protection for distribution feeders
• Stand-alone or component in automated substation
control system
• Interlocking scheme on distribution level by means of
Remote I/O features
• Throw over schemes (bus transfer scheme)
• Load shedding scheme based on frequency elements
Key Benefits
• Unparalleled security/safety – downed conductor detection
• Reliable Distributed Generation interconnection protection
• Dependable and secure – performance backed up by
many years of field experience
• Cost effective and flexible access to information – multiple
communication options and protocols
• Breaker monitoring – monitor breaker conditioning
through analog I/O, rich metering, breaking arcing current,
and trip counters
• Use high speed communications to reduce wiring and
installation costs – exchange inputs and outputs between
relays to achieve relay-to-relay interaction
• Reduce installation space requirements through compact
design – multifunction device that integrates protection
and control functions, programmable pushbuttons and
status LEDS, and communication interfaces
• Maintenance cost savings and simplification – modular
construction, common hardware, reduced stock of spare
parts, plug & play modules
• Application flexibility – multiple I/O options, programmable
logic (FlexLogic
™
), modularity, customize to specific
requirements
• Reduce system event analyzing time and cost – sequence
of event reports, oscillography, datalogging, IRIG-B time
synchronization
• Embedded IEC 61850 Protocol – no external protocol
converter required
Features
Protection and Control
• Downed conductor detection – high impedance faults
• Phase, neutral, ground or sensitive ground and negative
sequence IOCs and TOCs with directional control
• Sensitive directional power
• Breaker failure
• Breaker control
• Four-shot autorecloser with synchronism check
• Up to 80 digital input and 56 digital outputs
• Transducer I/Os (RTD, dcmA)
• Wattmetric zero-sequence directional function
Communications
• Networking options – Ethernet-fiber (optional redundancy),
RS485, RS422, G.703, C37.94
• Multiple protocols – IEC 61850, DNP 3.0 Level 2, Modbus RTU,
Modbus TCP/IP, IEC 60870-5-104, Ethernet Global Data (EGD)
• Direct exchange of Inputs/Outputs – exchange of binary
data between URs
Monitoring and Metering
• Metering – current, voltage, power, energy, frequency,
voltage and current harmonics, demand (current, power)
• Oscillography – 64 samples/cycle, up to 64 records
• Event Recorder – 1024 time tagged events, with 0.5ms
scan of digital inputs
• DataLogger – up to 16 channels with user selectable
sampling rate
• Fault Locator
User Interfaces and Programming
• Fr
ont panel display and keypad for local direct access,
with an RS232 port for local PC access
• User programmable local display, LEDs and pushbuttons
• Customize protection and control functions with
FlexLogic
™
FlexCurves
™
, and FlexElements
™
• Includes EnerVista LaunchPad - Simple relay setup and
programming
• Multi-language support – French, Chinese, Russian option
• Order must include complete catalog number of required
device
F60 Feeder Protection System