Operator`s manual

4.5 LADDER TROUBLE-SHOOTING GUIDE
PROBLEM PROBABLE CAUSE REMEDY
1. No hydraulic pressure a) PTO not engaged. a) Switch PTO to
at either Outrigger. "ENGAGED".
b) Ladder/Outrigger b) Pull valve out to
Selector Valve not select Outrigger.
pulled out.
c) Electric/PTO Pump c) Move switch to
Switch not in "Down" position.
correct position.
d) Pre-set engine rpm d) Increase engine rpm
is too low. setting to a
minimum of 1200.
2. PTO/Hydraulic Pump a) Pre-set throttle a) Reduce setting to
is noisy. setting is too a minimum of 1200.
high.
b) Hydraulic oil b) Fill the hydraulic
level too low. oil tank to the
correct setting on
the dip stick.
c) Valve on hydraulic c) Ensure valve 6
suction line (see Figure 5-2)
partially closed. is fully open.
3. Outrigger fails a) Ladder/Outrigger a) Pull valve out to
to operate. Selector valve not select Outrigger.
pulled out.
b) Hydraulic pressure b) Check hydraulic
too low. Pressure A
minimum of 1000 psi.
is required.
4. Ladder will not a) Ladder Bed Lock Assy a) Ensure the PTO Switch
elevate. not disengaged. is at "ENGAGED".
26