MDX-ETHERNET User Guide 13
Issue : a www.leroy-somer.com
4.8.2 Single PC to multiple MDX-ETHERNET using a single switch
Connecting multiple MDX-ETHERNET modules should be done using an industrial
grade switch. Each MDX-ETHERNET or PC is connected to the switch using a standard
RJ45 lead (patch lead).
Figure 4-4 Single PC to multiple MDX-ETHERNET modules using a switch
4.8.3 Single PC to multiple MDX-ETHERNET using a daisy chain
Connecting multiple MDX-ETHERNET modules should be done using daisy chain on
networks (see figure 4-5).
Other Ethernet network topologies can be used but care must be taken to ensure that
the system still operates within the constraints specified by the designer.
Figure 4-5 Connections with multiple switches
4.8.4 Connection of network subnets
When connecting multiple network subnets a router or firewall should be used to allow
effective management of network traffic. A subnet is identified by the change in the
network section of the IP address (see section 5.6.1 The IP address for more
information). A subnet boundary is usually designated by a router or firewall. The design
of larger networks, however, is beyond the scope of this document.
Switch
Non-crossover cable
Non-crossover cable
Non-crossover cable