12.6 Data format
The default data format is 2 cyclic channel OUT and IN, each cyclic data channel is
mapped to a drive parameter. See section 7 cyclic data and 8 non cyclic data for more
information.
12.7 Fieldbus option state
The operating status of the MDX-ETHERNET can be viewed in the fieldbus option state
parameter (Pr 15.06). When the MDX-ETHERNET is communicating successfully with
the master controller, Pr 15.06 will give Master read.
Table 12.5 MDX-ETHERNET operating status codes
If a mapping configuration error or network error is detected the drive may trip. Refer to
Section 12.8 Cyclic parameter number (mapping status) for details about the trip
display.
The maximum number of parameter data that is possible is 10 with only cyclic data.
NOTE
Fieldbus option state
Pr 15.06
Default N/A
Range 0 to 14
Access RO
Pr 15.06 LCD display Description
0 Setup in progress MDX Setup in progress.
1 Network init
The module is currently performing network-related initialisation
tasks. Telegrams now contains Process Data (if such data is
mapped), however the network Process Data channel is not yet
active.
2
Network Process Data
inactive
The network Process Data channel is temporarily inactive, wait
cyclic.
3IDLE
The network interface is idle. The exact interpretation of this
state is network specific. Depending on the network type, the
Read Process Data may be either updated or static
(unchanged).
4 Process active The network Process Data channel is active and error free.
5 Bus error There is at least one serious network error.
6 Wait web update
Wait a few minutes until Data base of new drive version is
loaded in MDX option. Do not switch off the product during this
period.
7 Host error
The module has ceased all network participation due to a host
application-related error. This state is unrecoverable, i.e. the
module must be restarted in order to be able to exchange
network data.
8 Option bus loss Communication between MDX option and Drive is lost.
9 reserved
10 reserved
11 reserved
12 Host supervising
Module is supervised by another network device. Perform
manual data handling.