Specifications
34
Smart and cutting edge design
Extensive lineup from 8HP to 48HP in 2HP increment
Connectable indoor unit capacity ratio up to 150%
Handles changes in the temperature difference
Simultaneous cooling and heating operation
using 1 refrigerant system
Cooling and heating can be freely selected for each
indoor unit to provide simultaneous cooling and heating
in rooms with large temperature differences.
Annual cooling operation
Energy saving of the operating
systems has been approved
as heating and cooling modes
can be operated at the same
time on the same air
conditioning piping system.
Our Heat recovery systems achieve high operating energy efficiency
by drawing heat from the room to be cooled and transferring it as
energy for rooms that are to be heated.
050
COP
Heating ratio
High
100 (%)
No-Heat Recovery model
Heating & Cooling
Mainly HeatingMainly Cooling
High pressure liquid
Low pressure gas
High pressure gas
Indoor unit
Outdoor unit
Cooling
Heating
RB unit
Heat
exchanger
EEV
Heat exchanger
Compressor
4 way valve
Large Building
The operation mode can be freely changed when there
are large temperature differences during the day, such
as between seasons.
Use annual cooling operation for the rooms and other
spaces that require constant temperature control
throughout the year.
35
Features
4-face heat exchanger
Heat exchange efficiency is significantly improved by
the introduction of a new 4-face heat exchanger that
increases effective surface area.
Front intake port
(corner cut air inhaling structure)
In multiple outdoor unit installations, the unique front
intake design improves airflow into the Heat Exchanger.
Energy saving technology that boosted operation efficiency
3 phase DC fan motor
Efficiency is substantially improved by high efficient
motor with sophisticated driver control. In addition,
low noise is realized by DC fan motor.
Sine-wave DC inverter control
High efficiency is realized by adoption of reduced
switching loss IPM.
Subcool heat exchanger
High Heat Exchange efficiency is achieved by using
an internal projection shape double pipe
construction.
High efficient compressor
Large capacity DC inverter
compressor
Large capacity high efficient DC twin rotary
compressor with excellent intermediate capability.
Powerful large propeller fan
By using CFD*
1
technology, a newly designed fan
achieves high performance and low noise operation.
*1. CFD = Computational Fluid Dynamics
For 24 HP Combination
Space saving
Energy efficiency
COP 12.6% UP
Space saving
combination
Energy efficiency
combination
(COP)
81012141618202224*
363432302826 38 40 42 44 46 48
2
3
4
5
(HP)
(COP)
162224*26283032343638
444240
(HP)
2
3
4
5
Top class high COP is achieved for all combinations by our unique heat exchanger structure,
high efficient DC twin compressor, and our own technologies.
Efficiency in actual operation
4.30
4.39
3.90
4.13
3.92
4.34
4.30
4.07
3.90
4.05
3.91
4.01
3.92
4.01
3.90
4.00
3.91
4.00
3.91
3.98
3.92
4.39
4.22
4.39
4.35
4.32
4.30
4.24
4.23
4.18
4.17
4.08
4.13
4.05