Specifications

High efficiency turbo fan with 3-dimensional blade
450mm
Heat exchanger
< Motor side >
Uneven airflow
Separation
phenomenon of
airflow
causes noise
: Spin direction : Airflow direction : Turbulent flow noise
< Motor side >
Heat exchanger
3-dimensional blade
High efficiency airflow distribution has been achieved by the introduction of a 3
dimensional blade which increases the air passing over the heat exchanger.
Previous blade
500mm
No airflow separation
Quiet
Powerful, wide airflow and quiet operation
Models
AUXD18GALH
AUXD24GALH
AUXA30GALH
AUXA36GALH
AUXA45GALH
AUXA54GALH
Previous turbo fan
Air passing through the heat exchanger was uneven and the air
would only flow close to the ceiling.
Fast
Slow
Wind velocity
5.6
6.3
39
1,150
940
870
36
30
29
Cooling
Heating
High
Med
Low
High
Med
Low
Liquid (Flare)
Gas (Flare)
Drain
kW
W
m
3
/h
dB(A)
mm
mm
mm
kg
kg
Model name
Power source
Capacity
Input power
Airflow rate
Sound pressure level
Dimensions (H x W x D)
Weight
Connection
pipe diameter
Cassette
Grille
G* : GY(FUJITSU) ; GG(GENERAL)
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27ÛCDB / 19ÛCWB, and outdoor temperature of 35ÛCDB / 24ÛCWB.
Heating : Indoor temperature of 20ÛCDB / (15ÛCWB), and outdoor temperature of 7ÛCDB / 6ÛCWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
AUXD18GALH
230V ~, 50Hz
AUXD24GALH AUXA30GALH AUXA45GALHAUXA36GALH AUXA54GALH
246 x 840 x 840
22
288 x 840 x 840
27
ø9.52
ø25 (I.D.) ; ø32 (O.D.)
UTG-UG*A-W
50 x 950 x 950
5.5
Model name
Dimensions
(H x W x D)
Weight
Specifications
9.0
10.0
59
1,600
1,300
1,100
40
38
33
11.2
12.5
80
1,800
1,300
1,100
44
38
33
14.0
16.0
119
2,000
1,370
1,100
47
39
33
7.1
8.0
46
1,280
1,040
870
38
33
29
ø15.88
12.5
14.0
99
1,900
1,370
1,100
46
39
33
ø19.05
60
Indoor units
61
6
1
18
24
30
36
45
54
Model code
3.0
3.0
3.2
3.2
3.2
3.2
Standard mode
3.5
3.5
3.6
4.2
4.2
4.2
High ceiling mode
The maximum height from floor to ceiling (m)
Models: AUXD18 / AUXD24 (Slim type)
AUXA30 / AUXA36 / AUXA45 / AUXA54
Dimensions (Unit : mm) ( ) : AUXD18 / AUXD24
Detachable
Grille corner
Adjustment can be done
just taking off the corner part
Ceiling panel
Improvement of the airflow distribution
Adjustment of hanger position is
possible after installation
Parallel
apertures
One way aperture installation
High lift drain pump
High ceiling mode
The louvre design distributes air
leaving a space between the
chassis and the ceiling allowing far
and wide air flow distribution.
This cassette can be installed up to a height of 4.2m (36/45/54).
Much less temperature irregularity
happens by spreading airflow widely
Bottom view
Front part
Ceiling
Rear part
Round louvre
Optional parts
IR Receiver Unit :
Air Outlet Shutter Plate :
Panel Spacer :
Insulation Kit for High Humidity :
Wide Panel :
Fresh Air Intake Kit :
UTY-LRH*B1
UTR-YDZC
UTG-BGYA-W
UTZ-KXGA / UTZ-KXGB
UTG-AGYA-W
UTZ-VXGA
H*: HY(FUJITSU), HG(GENERAL)
796
Hanging bolt position
Drain hose
358
Ƒ 840 : Indoor unit
607
420
699
Hanging bolt position
Ƒ 860 to 910
Ceiling opening
142
142
Ceiling
950
IR receiver
(Option)
950
(Control) Box
200
10
358 278
60
44
40
Wire hole
Gas pipe
Liquid pipe
140
298(256)
Max.
850mm