Specifications
66
66
Low energy consumption by DC fan motor.
Selectable with a wide range of static pressure.
Models
ARXA24GBLH
ARXA30GBLH
ARXA36GBLH
ARXA45GBLH
Slim & Compact design
In the case of bottom return air connection, not only does the indoor
unit design allow for installation in a narrow ceiling space of up to
270mm, Further space savings have been achieved by mounting
the electrical control box internally inside the chassis.
Low energy consumption by
high efficiency DC fan motor
Improved motor efficiency from previous model.
270mm
1,200 1,135mm
Control box is now included as
part of the main chassis
One touch operating and easy
to install long life filter
(Optional Parts)
24 model 30 / 36 / 45 model
30
/3
6/
45
dl
7.1
8.0
94
1,280
990
840
0 to 150
40
31
27
23
36
ARXA24GBLH
Cooling
Heating
High
Med
Low
High
Med
Low
Liquid (Flare)
Gas (Flare)
Drain
ARXA30GBLH
9.0
10.0
108
1,410
1,280
1,150
0 to 150
50
34
32
29
ARXA36GBLH
11.2
12.5
194
1,840
1,600
1,470
0 to 150
50
37
35
33
40
ARXA45GBLH
12.5
14.0
240
1,970
1,860
1,640
0 to 150
60
41
38
36
kW
W
m
3
/h
Pa
dB(A)
mm
kg
mm
Model name
Power source
Capacity
Input power
Airflow rate
Static pressure range
Standard static pressure
Sound pressure level
Dimensions (H x W x D)
Weight
Connection
pipe diameter
Note : Specifications are based on the following conditions. Cooling : Indoor temperature of 27ÛCDB / 19ÛCWB, and outdoor temperature of 35ÛCDB / 24ÛCWB.
Heating : Indoor temperature of 20ÛCDB / (15ÛCWB), and outdoor temperature of 7ÛCDB / 6ÛCWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
ø9.52
ø25 (I.D.) ; ø32 (O.D.)
230V ~, 50Hz
270 x 1,135 x 700
ø15.88 ø19.05
Specifications
Indoor units
67
67
Two-direction drain
piping
Optional parts
1.Control box
2.Fan casing
3.Fan
4.Motor
New model
1
4
3
2
Bottom panel: 2 pieces
The maintenance of the motor and fan can be easily carried out by removing
the rear panel and the lower part of the casing while leaving the main
chassis installed.
Selectable with a wide range of
static pressure
It is possible to change of static
pressure range 0 to 150Pa.
Two-direction drain piping
Duct indoor unit
Installation styles
Embedded in Ceiling Hanging from Ceiling
Easy maintenance
See below for the case of rear suction type
Can be installed for various location
Remote Sensor Unit :
Long Life Filter :
Flange (Square) :
UTY-XSZX
UTD-LF25NA
UTD-SF045T
Flange (Round) :
IR Receiver Unit :
Drain Pump Unit :
UTD-RF204
UTB-YWC
UTZ-PX1NBA
It can be installed in such
locations as high-rise
condominiums by low static
pressure design.
It can also be installed in wide
spade when high static
pressure is required, such as
for offices.
Easy setting by using remote controller
The change of static
pressure range is possible
by remote controller
*Service accessibility must be allowed for when installing the product.
Please consult the installation manual for the necessary service access size.
Refrigerant piping flare connection (Liquid) :
Refrigerant piping flare connection (Gas) :
Drain piping connection (Drain pipe)
2
1
3
Rear view
Top view
Side view (R)
Side view (L)
Front view
240
270
107
1015
1135
173
161
447(Bolt pitch)
1177(Bolt pitch)
Outlet
270
32
ø200
(knock
out hole)
240
121
P.C.D. ø225
114
66
32
1
3
3
2
168
281
240
700
138
138
264 264 264
ø205 hole
82
75
Models: ARXA24 / ARXA30 / ARXA36 / ARXA45
Dimensions (Unit : mm)
Static pressure range
0 to 150 Pa