Specifications

82
3,600
m
Max. transmission
line length
Outdoor
unit
Touch Panel
Controller
Wired
Remote Controller
(Touch panel)
Wired
Remote Controller
Indoor unit
(Cassette)
Group
Remote Controller
Indoor unit
(Duct)
External Switch
Controller
Simple
Remote Controller
Wireless
Remote Controller
Simple
Remote Controller
IR Receiver
unit
Central Remote
Controller
System
Controller
Transmission line
Module link
Remote Controller line
(2 wires)
Remote Controller line
(3 wires)
Group Remote
Controller line
Signal line
(single system)
USB cable
Ethernet
LONWORKS
®
Network
Refrigerant system 1 Refrigerant system 2
USB Adaptor
USB
Adaptor
USB
Adaptor
USB Adaptor
Network Convertor UTY-VGGXZ1
UTY-ABGX
Network Convertor
UTY-VGGXZ1
Signal Ampli¿er
UTY-VSGXZ1
Web Monitoring Tool
UTY-AMGX
Web Monitoring Tool
Trouble free operation at all times
by remote monitoring system.
Transmission line
line is non-polar 2-conductor.
Service Tool
Extensive monitoring and analysis
functions for installation and maintenance.
2 Remote Controllers
Indoor unit can be controlled
from both remote controllers.
System without Remote Controller
Together with Touch Panel Controller, it is
possible to build non remote controller system.
Group Remote Controller
Maximum 8 remote controller groups can be controlled
Central Remote Controller
Maximum 100 indoor units can be controlled.
Touch Panel Controller
One Touch Panel Controller can control
up to 400 groups / 400 indoor units.
System Controller UTY-APGX
Maximum 1,600 indoor units can be controlled.
Air conditioning control
Operation monitoring
Status monitoring system
Electricity charge calculation
IR Receiver Unit
Cassette type indoor unit
can be controlled with
Wireless Remote Controller
IR Receiver Unit
Duct type indoor unit can be controlled with
Wireless Remote Controller.
Service Tool
UTY-ASGX
Single system
(VRF network system side)
(Monitoring side)
(Monitoring side)
(Monitoring side)
(Remote / Monitoring side)
BACnet
®
GatewayBACnet
®
LONWORKS
®
BACnet
®
BACnet
®
Operator
Workstation (B-OWS)
NW 1
NW 2
NW 3
NW 4
Internet
or
Public Telephone Line
Internet
or
Public Telephone Line
Remote Controller line
Maximum 16 units can be controlled
External Switch Controller
Indoor units can be controlled by combining
with Card-key switch such as hotel room.
Card key
LONWORKS
®
Network
Building Management System
RB unit
(Single)
Network
Convertor
for L
ONWORKS
®
UTY-VLGX
RB unit
(Multi)
• Wiring construction of the control system is made of power source wiring, transmission wiring and remote controller wiring.
• Total wiring length (total length of transmission line) can be extended up to 3,600m (by using signal amplifiers).
83
1
16
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
30
-
-
-
-
-
-
-
Simple
Remote
Controller
UTY-RHK*
Max. controllable remote controller groups
Max. controllable indoor units
Max. controllable groups
On / Off
Operation mode setting
Fan speed setting
Room temp. setting
Room temp. set point limitation
Test operation
Up/down air direction flap setting
Right/left air direction flap setting
Group setting
RC prohibition
Anti freeze setting
Economy mode setting
Error
Defrosting
Current time
Day of week
R.C. prohibition
Cooling/heating priority
Address display
Room temp
Multi language
Summer time
Name registration
Backlight
2D floor layout / 3D building display
Schedule timer
On/off timer
Sleep timer
Program timer
Auto off timer
Day off
Min. unit of timer setting (Minutes)
Status monitoring system
Electricity charge apportionment
Error history
Emergency stop
Remote management
Energy saving management
E-mail notification for malfunction
Key lock
Item
Model name
Period
On/off, Temp,
Mode, Times per day
R*: RY (FUJITSU), RG (GENERAL) K*: KY (FUJITSU), KG (GENERAL) H*: HY (FUJITSU), HG (GENERAL) G*: GY (FUJITSU), GG (GENERAL)
*1 "Operation mode" setting is not available for this model.
*2 This function is available only through external input control.
Ɣ
: Supported
Ɣ
: Optional function
: Not supported yet
*1
Control Timer Display Air conditioning control function
Wireless
Remote
Controller
1
16
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
5
-
-
-
-
-
-
-
-
UTY-LNH*
400
400
400
-
-
-
-
Year
144
-
-
-
-
10
-
Password
setting
UTY-ALGX
System
Controller Lite
Software
1600
1600
1600
-
-
-
Year
144
-
-
-
-
10
-
UTY-APGX
System
Controller
Software
Password
setting
400
400
400
-
-
Year
20
-
-
-
-
-
10
-
-
-
-
*2
Password
setting
Touch
Panel
Controller
UTY-DTG*
Simple
Remote
Controller
UTY-RSK*
1
16
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
30
-
-
-
-
-
-
-
UTY-RNR*
1
16
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Week
8
-
-
10 •
30
-
-
-
-
-
-
Wired Remote
Controller
(Touch panel)
Child lock
8
128
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Week
4
-
-
-
-
-
10
-
-
-
-
-
-
Group
Remote
Controller
UTY-CGG*
Child lock
Central
Remote
Controller
100
100
16
-
-
-
Week
20
-
-
-
-
10
-
-
-
-
Password
setting
UTY-DCG*
*2
UTY-RLR*
1
16
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Week
4
-
-
-
30
-
-
-
-
-
-
Wired
Remote
Controller
Child lock