Specifications
86
Individual Controller
• Various timer setup (ON / OFF / WEEKLY) are possible.
• The room temperature can be controlled by detecting the temperature accurately
with Built-in thermo sensor.
• When a failure occurs, the error code is displayed.
• Error history. (Last 16 error codes can be accessed.)
• 2-wire type
UTY-RLR*
Max. controllable
indoor units
16
UTY-RLR*
DC 12V
120 x 120 x 17
170
Specifications
Model name
Power Supply
Dimensions (H x W x D) (mm)
Weight (g)
DC12V is supplied by indoor unit. R* : RY(FUJITSU), RG(GENERAL)
Functions
In addition to the individual control, weekly timer, and various
energy saving controls can be realized using only one remote
controller.
High performance and compact size
• The setting temperature automatically returns to the previously
set temperature.
• The time range in which the set temperature can be changed is
30 to 240 minutes.
Set temperature auto return
High visibility and
easy operation
Auto-off timer
Individual
control
Thermo
sensor
Weekly
timer
Auto OFF
timer
• The indoor unit automatically turns off after a set time has passed.
Set temperature upper and lower limit setting
• The set temperature range can be set for each operation mode.
(Cooling / Heating / Auto)
• "Mode", "Set Temp", and "Fan"
are displayed at large size on
the top screen.
• Each function to be set is
indicated by an icon.
• Control guide is displayed and
operation is simple and
straightforward.
Setting temp.
Cooling operation
24°C
22°C
Set temperature change Auto return
Time
Settable time range
30 to 240 minutes
Setting temp.
Heating operation
25°C
23°C
Set temperature change Auto return
Time
Settable time range
30 to 240 minutes
Original temp.
setting range
Lower limit
setting
During Cooling
30°C
25°C
18°C
Original temp.
setting range
Upper limit
setting
During Heating
30°C
25°C
16°C
Set contents can be displayed
clearer with large LCD.
Sophisticated control buttons
Simple operation with easy
4-way navigation pad
Operation
status
Auto OFF Auto OFF
OFF
ON
Auto-off timer can
be set from 30 to
240 minutes
Weekly timer function
• Not only time setting On / Off, but also setting of the operation
mode and set temperature can be set by Weekly timer function.
4 types (ON, OFF, ON, OFF) can be set on every day of the week in a week.
24°C
ON
8:00 12:00 13:00 17:00
OFF ON OFF
Working hour Working hour
N E W
87
Compact remote controller provides access to
basic functions
UTY-RSK* / UTY-RHK* (Without Operation mode)
• Up to 16 indoor units can be controlled with one remote controller.
• Suitable for hotels or offices as it is easily operated with no complex functions.
Max. controllable
indoor units
16
Specifications
Model name
Power Supply
Dimensions (H x W x D) (mm)
Weight (g)
DC 12V
120 x 75 x 14
DC12V is supplied by the indoor unit. K* : KY(FUJITSU), KG(GENERAL)
UTY-RSK*
90
UTY-RHK*
UTY-RSK*
UTY-RHK*
Without Operation mode
• Provides access to basic operations, such as Start / Stop, Fan
control, Operation mode switching, and Room temperature
setting.
• A large On / Off button is provided in the centre of the remote
controller for easy operation.
• Can be used jointly with other individual control unit.
• Following an error display, diagnostics can be carried out on the
controller.
User-friendly operation
• Backlight enables easy operation in a
darkened room.
• Backlight activates during all button
operations, and lasts 10 seconds in
Operation mode and 5 seconds in stop
mode after a button is pressed.
Backlight
Functions summary
Can be mounted on the European Mounting Box (Installation
dimension: 60mm) or the JIS Built-in Box (Installation dimension:
83.5mm).
Simple installation
European switch box JIS built-in box
*1: "Operation mode" setting is not available.
It is recommend to use together with other type controller.
83.5mm
60mm
Functions
Operation
Model
UTY-RHK*UTY-RSK*
On / Off
Fan control
Operation mode
Room temp. setting
*1