Specifications
On site central control
Remote central control
System Controller may be used on site or remotely over various
networks for remote central control. System Controller requires
2 softwares working together. VRF Controller runs on site and
communicate with VRF system. VRF Explorer runs remotely and
provides user interface and communicate with the VRF Controller.
VRF Controller and VRF Explorer program may run in a single PC
or in different PCs separated by network. By using VRF Explorer
software, one PC can perform central control of 10 VRF system
sites with max. 20 buildings per site.
Max. 4 VRF network systems per site
Building Management Company A
(In charge of the day shift)
Internet
or
Telephone Line
or
LAN
Internet
or
Telephone Line
or
LAN
Building management company,
management center, etc.
Building
Management Company B
(In charge of the night shift)
Security Company
Headquarters Management Center
A maximum of
10 locations, such as
offices or factories
1 VRF Explorer can control or monitor up to 10 sites.
1 VRF Controller can be monitored from any number
of VRF Explorers (Up to 5 connections simultaneously).
Office Management Center
VRF Explorer
VRF Explorer
VRF Explorer
VRF Explorer
VRF Explorer
VRF Explorer
VRF Controller
VRF Controller
Internet
or
Telephone Line
or
LAN
VRF Explorer
VRF Controller
Central Monitoring Screen
for all Properties
Special Property Detailed Monitoring Screen
96
Remote management
A variety of energy saving operations can be set and managed
depending on the season, weather, and time period. Excellent energy
saving operation is performed while keeping users comfortable.
Energy saving management
Peak cut operation
Outdoor unit capacity save
Outdoor unit capacity save switches the outdoor unit capability upper
limit to suppress power consumption during hot summers and cold
winters by averaging the power saving effect of each refrigerant
system. You can select from 50% or more of the capacity upper limit.
Indoor unit rotation operation
The operation of indoor units can be automatically rotated within a
group in accordance with the set annual schedule to reduce power
consumption while maintaining comfort. The indoor unit operation
stoppage rate can be selected.
A power meter is connected to detect the total power consumption
while shifting the indoor unit set temperature, set the indoor unit
forced thermostat off, and taking other measures to carefully control
the power consumed
while maintaining comfort
and conducting control to
maintain the target power
consumption set for each
time. The indoor units to
be controlled can be
freely grouped and the
control level can be set.
Centralized Controller
Outdoor unit capacity
control screen
Otd it it
Power consumption
Time
Outdoor unit
capacity
upper limit
Hot day of
summer
Cold day of
winter
Indoor unit rotation screen
Id
it
t
ti
Energy saving graph data:
This graph compares the electricity
consumption with the previous month
and previous year to make it easy to
analyze the energy saving effect.
Energy Saving Management Main Screen
Forced thermostat off range
Target power consumption
Shows change in power consumption by time
Outdoor unit stop range
Ideal control line
(Use of average
power consumption)
for System Controller
for System Controller Lite UTY-PLGXR1
Option
Standard
for System Controller UTY-PEGX
for System Controller Lite UTY-PLGXE1
Option
Option
97
FUNCTIONS SUMMARY
• Microsoft
®
Windows Vista
®
Home Premium (32-bit) SP2, Windows Vista
®
Business (32-bit) SP2
• Microsoft
®
Windows
®
7 Home Premium (32-bit or 64-bit) SP1, Windows
®
7 Professional (32-bit or 64-bit) SP1
• Microsoft
®
Windows
®
8 (32-bit or 64-bit), Windows
®
8 Pro (32-bit or 64-bit)
• Microsoft
®
Windows
®
8.1 (32-bit or 64-bit), Windows
®
8.1 Pro (32-bit or 64-bit)
[Supported languages]
English, Chinese, French, German, Russian, Spanish, and Polish
Personal computer system requirements
Operating system
Interface
Software
Optical drive
•Personal computer that satisfies the following system requirements
•Echelon
®
U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for each VRF Network.)
HDD 40 GB or more of free space
Display 1024 x 768 or higher resolution
•Ethernet port (for getting access to the Internet using LAN)
or Modem (for getting access to the Internet using Public Telephone Line)
•USB ports (Maximum of 6 ports)
(Required only for the Server PC that works as VRF Controller)
- Maximum of 2 USB ports are required for WibuKey connection
- Maximum of 4 USB ports are required for Echelon
®
U10 USB Network Interface
* Maximum number of required USB port depends on the applicable
system configuration.
•Ethernet port (for getting access to the Internet using LAN)
or Modem (for getting access to the Internet using Public Telephone Line)
•USB ports (Maximum of 5 ports)
(Required only for the Server PC that works as VRF Controller)
- Maximum of 4 USB ports are required for WibuKey connection
- 1 USB port is required for Echelon
®
U10 USB Network Interface
* The maximum number of required USB port depends on the applicable
system configuration.
Adobe
®
Reader
®
9.0 or later
DVD-ROM drive
CPU
Intel
®
Core
TM
i3 2 GHz or higher
Graphic accelerator
Microsoft
®
DirectX
®
9.0c compatible
Memory
• 2 GB or more (for Windows Vista
®
and Windows
®
7 [32-bit])
• 4 GB or more (for Windows
®
7 [64-bit], Windows
®
8, and Windows
®
8.1)
*1:Software protection key to be inserted in a USB slot running System Controller or System Controller Lite.
System Controller or System Controller Lite may only run on a PC with Wibu Key. However, WibuKey is not required for remote VRF Explorer software.
Type
Model name
UTY-APGX
1
1
System controller
For System controller For System controller Lite
UTY-PEGX
1
1
Energy manager
Electricity charge apportionment
UTY-ALGX
1
1
System Controller
Lite
Remote access
UTY-PLGXR1
ņ
1
UTY-PLGXA1
ņ
1
Energy saving
UTY-PLGXE1
ņ
1
WibuKey*
1
(Software protection key)
DVD-ROM
<Packing list>
Max. VRF networks supported
Max. indoor unit / remote controller groups per VRF network
Max. outdoor units per System controller
Max. indoor units / remote controller groups per System controller
Max. outdoor units per System controller
Multi site display
Number of building / 1 site
Number of floor per 1 site
Number of floor per 1 building
3D graphical layout view
2D graphical layout view
List display
Tree display
Group display
Error notification
Audible alarm
Error e-mail notification
Error history
Operation history
Control history
On/Off
Operation mode
Room temperature
Fan speed
Air flow direction
Economy mode
Room temperature set point limitation
Test operation
Antifreeze
Outdoor unit low noise setting
Remote control prohibition setting
Temperature upper and lower limit setting
Filter sign reset
Memory operation
Pattern operation
Annual Schedule
Special day setting
On /off per day
On / off per week
Day off
Min. unit of timer setting (Minutes)
Low noise mode Weekly schedule
Remote monitoring
Remote operation control
Remote function setting
Apportionment charge/bill calculation
Tenant (block) setting
Common facilities apportionment setting
Rated power consumption allotment setting
Individual calculation at cooling and heating
Electricity meter supported
Indoor unit rotation
Peak cut control
Outdoor unit capacity save
Record of energy saving operation
Energy saving information
Power consumption monitor
Electricity meter supported
Database import/export
Automatic clock adjustment
Multi language
4
400
100
1600
400
10
20
200
50
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
72
504
ż
10
ż
ż
ż
ż
ż
ż
ż
ż
-
-
-
-
-
-
-
-
ż
ż
7 languages
1
400
100
400
100
10
-
-
-
-
-
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
ż
72
504
ż
10
ż
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ż
ż
7 languages
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ż
ż
ż
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ż
ż
ż
ż
ż
ż
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ż
ż
ż
ż
ż
ż
ż
-
-
-
System
specification
Function Type
System controller
UTY-APGX
UTY-ALGX
System controller lite
Site
supervision
Error
management
History
Operation
control
Schedule
Remote
managemment
Electricity
charge
apportionment
Energy
saving
management
Others
Individual
control
Individual
management
Other
UTY-PEGX
Option
UTY-PLGXR1
Option
UTY-PLGXA1
Option
UTY-PLGXE1
Option
ż
: Available.
-
: Not available.
*:Power calculation application software is necessary, please contact the local FGL representative.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
ż*
ż
ż
ż
ż
ż
ż
ż
ż
-
-
-
Option Option
System Controller System Controller Lite