Specifications

110
Ventilation
11
0
Models
UTZ-BD025B
UTZ-BD035B
UTZ-BD050B
UTZ-BD080B
UTZ-BD100B
Energy recovery ventilator unit offers
maximum comfort and greater energy
savings.
Specifications
Input power
Air flow rate
External static pressure
HEAT EXCHANGE
VENTILATION
NORMAL
VENTILATION
Rated flow rate
Model No.
250 m
3
/h
UTZ-BD025B
350 m
3
/h
UTZ-BD035B
500 m
3
/h
UTZ-BD050B
800 m
3
/h
UTZ-BD080B UTZ-BD100B
1000 m
3
/h
Power source
W
m
3
/h
Pa
%
%
%
dB*
dB*
W
m
3
/h
Pa
mm
kg
°C
%
mm
Extra high / High / Low
Extra high / High / Low
Extra high / High / Low
Extra high / High / Low
Extra high / High / Low
Extra high / High / Low
Heat exchange ventilation and normal ventilation
Heat exchange ventilation
When a room is cooled or heated, the exhausted cooling / heating
energy is recovered by heat-exchange ventilation.
Normal ventilation
The operation is used during periods when the room space requires
no cooling or heating effect, i.e. when there is minimal temperature
difference between the indoor and outdoor environments.
Adopts a highly efficient counter-flow
heat exchange element
Heat exchanger
Outside air
Exhaust air
Supply air
Room air
128 / 123 / 96
250 / 250 / 190
105 / 95 / 45
190 / 185 / 168
350 / 350 / 240
140 / 60 / 45
289 / 225 / 185
500 / 500 / 440
120 / 60 / 35
418 / 378 / 295
800 / 800 / 630
140 / 110 / 55
464 / 432 / 311
1000 / 1000 / 700
105 / 80 / 75
75 / 75 / 77
63 / 63 / 65
70 / 70 / 72
31.5 / 30.5 / 26.5
128 / 123 / 96
250 / 250 / 190
105 / 95 / 45
31.5 / 30.5 / 26.5
882 x 599 x 270
29
150
-10 ~ 40
85
75 / 75 / 78
66 / 66 / 71
69 / 69 / 73
33 / 31 / 25.5
190 / 185 / 168
350 / 350 / 240
140 / 60 / 45
33 / 31 / 25.5
1050 x 804 x 317
49
150
-10 ~ 40
85
75 / 75 / 76
65 / 65 / 68
71 / 71 / 74
37.5 / 37 / 34.5
418 / 378 / 295
800 / 800 / 630
140 / 110 / 55
37.5 / 37 / 34.5
1322 x 884 x 388
71
250
-10 ~ 40
85
75 / 75 / 79
65 / 65 / 70
71 / 71 / 76
38.5 / 37.5 / 34.5
464 / 432 / 311
1000 / 1000 / 700
105 / 80 / 75
40.5 / 39.5 / 36.5
1322 x 1134 x 388
83
250
-10 ~ 40
85
75 / 75 / 76
62 / 62 / 64
67 / 67 / 69
37.5 / 35.5 / 32.5
289 / 225 / 185
500 / 500 / 440
120 / 60 / 35
38.5 / 38 / 32.5
1090 x 904 x 317
57
200
-10 ~ 40
85
Sound pressure level
Input power
Air flow rate
External static pressure
Sound pressure level
Temperature Exchange
Efficiency
Energy Exchange
Efficiency Cooling
Energy Exchange
Efficiency Heat pump
Extra high / High / Low
Extra high / High / Low
Extra high / High / Low
Extra high / High / Low
Extra high / High / Low
Dimensions (W × D × H)
Weight
Outlet duct diameter
Operation range
Maximum humidity
220 - 240V, 50Hz
* The noise level must be measured 1.5 m below the centre of the unit.
UTZ-BD025B UTZ-BD035B UTZ-BD050B
UTZ-BD080B UTZ-BD100B
U
TZ-BD025
B
UTZ-
BD03
5B
B
UTZ-BD050B
U
TZ-BD080B
U
TZ-BD100B
TZ
BD03
5B
UTZ BD05
0
111
Energy saving
20%
111
Dimensions (Unit : mm)
Models: UTZ-BD025B / UTZ-BD035B / UTZ-BD050B / UTZ-BD080B / UTZ-BD100B
810
599
315
142
600
655
19
270
135
159
882
414
95
219
144
978
804
580
112
600
860
19
317
159
182
1050
470
70
162
144
1018
904
640
132
600
960
19
317
159
182
1090
470
127
210
194
1250
884
428
228
600
940
19
388
194
218
1322
612
85
258
242
1250
1134
678
228
600
1190
19
388
194
218
1322
612
85
258
242
Maintenance space
Maintenance opening
UTZ-BD025B
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B
Slim shape and easier installationEnergy efficiency and ecology
Features of heat exchange element
Quiet operation
Extended range of an external
static pressure
Reverse mountable direct air supply /
exhaust system
Energy consumption is dramatically reduced
by using a counterflow heat-exchange
element. Air conditioning load is reduced by
approximately 20%, resulting in significant
energy savings. Recovers up to 77% of the
heat in the outgoing air.
Counter-flow heat exchange element used for reduced noise and
slimmer, more compact body shape.
Adoption of straight air supply / exhaust system: Duct design
is simplified because the air supply / exhaust ducts are straight.
Since each unit can be mounted in reverse position, only one
inspection hole is needed for two units: Two units can share
one inspection hole so duct work is easier and more flexible.
With the cross-flow element, air moves in a straight line across the
element. With the counter-flow element , air flows through the
element for a longer time (longer distance) ,so the heat-exchange
effect remains unchanged.
Significantly reducing low pressure loss and noise allows low-noise
operation.
An external static pressure is improved by adopting a powerful fan
motor.
This allows for application in a wide variety building.
Other element
(Cross-flow element)
Fujitsu element
(Counter-flow element)
Straight
unit
Reverse
mounted
unit
Outside airExhaust air Exhaust air
Supply air
Room air Room air
Inspection
hatch
Inspection
cover
UTZ-BD025B
Height
270mm
UTZ-BD035B/BD050B
Height
317mm
UTZ-BD080B/BD100B
Height
388mm
ys ape