Step #5: Select the Machine Values Folder
Select the Machine Input process values of
Sensors 1 thru 8 for logging. These inputs
usually consist of compressor suction and
discharge pressures and temperatures. These
values can be viewed in real-time from the
Machine Inputs screen of the Maintenance
directory.
Select the sensor and press the Change button.
Scroll down to access sensors 6 - 8.
Return to the Logging\Data directory by
pressing the Back button.
Step #6: Select the UUT Values Folder
Use this screen to enable Units Under Test data
logging for UUT1 thru UUT8. These values can
be viewed in real-time in the UUT Temperatures
screen of the Events directory.
Select the UUT and press the Change button.
Scroll down to access UUTs 6 - 8.
Return to the Logging directory by
pressing the Back button.
Step #7: Start Logging Operation
From the Logging directory, select the Setup
folder. The screen at left appears. Here you set
up and start the logging operation.
To change the logging interval, select the
parameter and enter the time in seconds
on the keypad. The allowable range is 1 to
3600 seconds.
To change the file size, select the
parameter. Press Change and enter the
size in the keypad that follows. Range is
from 0.25 to 5.0 Megabytes. The upper
limit is dynamically calculated based upon
available space on the internal Storage
Card.
To enable logging, select the parameter
and press the Change button.