Specifications

Synergy Nano Technical Manual, Revision -
17.6 Synergy Nano Plus Wiring
17.4.1 Olympic Board Mounting
The Synergy Nano Plus is designed to work in split systems where the Synergy Nano is
mounted on the front of the equipment within reach of the operator and the Olympic I/O
Controller is in the control box in close proximity to the sensor and power controller wiring.
One ribbon cable connection is required between the Synergy Nano and the Olympic board;
this is a serial communications cable. A +/- 12 VDC power supply is also required for the
Olympic board as identified in the figure below.
Splitting the system provides both operator convenience and wiring convenience. In certain
applications the touch screen may be required to be remote from the chamber and not
mounted on the chamber. This can be required when the equipment must operate in an
explosion-proof area. A fiber-optic extender kit (P/N TE1972) can be used to separate the
Synergy Nano and the Olympic board by distances up to 50 feet. Separation distances up to
several kilometers are supported by special order. Consult the factory for more information.
Synergy Nano Plus Rear View
Expanded Configuration
X1
Power
X6
10/100
Ethernet
X7
USB Device
X8
Olympic Cable
Connector to
P13