Specifications
Synergy Nano Technical Manual, Revision -
Page 320
Description Command Root Command
Usages
Command Syntax Range,
Units
Command
Example
Response Example
RB1H Query ? RB1H 0 - 7 Seconds ? RB1H 4.000
Dead Band, Ch 1 DB1 DB1 Set = DB1 ARG1 -25 to 25 C -45 to 45 F = DB1 5 OK
DB1 Query ? DB1 -25 to 25 C -45 to 45 F ? DB1 5.00
Prop Band, Ch 1
Cool
PB1C PB1C Set = PB1C ARG1 0 to 50 C 0 to 90 F = PB1C 10 OK
PB1C Query ? PB1C 0 to 50 C 0 to 90 F ? PB1C 10.00
Reset, Ch 1 Cool RS1C RS1C Set = RS1C ARG1 0 - 09.999 Repeats / Minute = RS1C .700 OK
RS1C Query ? RS1C 0 - 09.999 Repeats / Minute ? RS1C 0.070
Rate, Ch 1 Cool RT1C RT1C Set = RT1C ARG1 0 - 09.999 Minutes = RT1C 1 OK
RT1C Query ? RT1C 0 - 09.999 Minutes ? RT1C 1.000
Cycle Time, Ch 1
Cool
CT1C CT1C Set = CT1C ARG1 1 - 60 Seconds = CT1C 7 OK
CT1C Query ? CT1C 1 - 60 Seconds ? CT1C 7.00
Rate Band, Ch 1
Cool
RB1C RB1C Set = RB1C ARG1 0 - 7 Seconds = RB1C 4 OK
RB1C Query ? RB1C 0 - 7 Seconds ? RB1C 4.000
Cascade CH1
Enabled **
CAS1_
ENABLED
= CAS1_ENABLED ARG1 ARG1:
0 - Disabled
1 - Enabled
= CAS1_ENABLED 1 OK
? CAS1_ENABLED 0 - Disabled
1 - Enabled
? CAS1_ENABLED 1
Channel 1
Cascade Sensor
**
CSS1 CSS1 Set = CSS1 ARG1 ARG1 - ID of the Sensor. 100 - 999. = CSS1 120 OK
CSS1 Query ? CSS1 See the user manual for numeric
codes.
? CSS1 120
CH 1 Cascade
High Limit **
C1HL C1HL Set = C1HL ARG1 - 200 to 500 C -326 to 932 F = C1HL 200 OK
C1HL Query ? C1HL - 200 to 500 C -326 to 932 F ? C1HL 200.00
CH 1 Cascade
Low Limit **
C1LL C1LL Set = C1LL ARG1 - 200 to 500 C -326 to 932 F = C1LL -100 OK
C1LL Query ? C1LL - 200 to 500 C -326 to 932 F ? C1LL -100.00
CH 1 High Max.
Delta** (Positive
Deviation Limit)
CH1HMAXD
ELTA
CH1HMAXDELT
A Set
= CH1HMAXDELTA ARG1 0 to 50 C 0 to 90 F = CH1HMAXDELTA 10 OK
CH1HMAXDELT
A Query
? CH1HMAXDELTA 0 to 50 C 0 to 90 F ? CH1HMAXDELTA 10
CH 1 Low Max.
Delta** (Negative
Deviation Limit)
CH1LMAXDE
LTA
CH1LMAXDELT
A Set
= CH1LMAXDELTA ARG1 0 to 50 C 0 to 90 F = CH1LMAXDELTA 10 OK