Specifications
Synergy Nano Technical Manual, Revision -
Page 74
Ambient Device
This output is used when cooling is required with humidity control
Output is either Time Proportioning or On/Off
L7 Ambient Cooling Turn On Percent cooling required to turn on the cooling
compressor
L8 Heat Ambient Cooling Turn Off Percent heat required to turn off the cooling compressor
L9 Ramp Up Cooling Temperature at which the cooling compressor is turned
off while heating
Affected By: Default Value: Range:
Channel 2 Proportional Band Heating 42 0 - 50 Degrees C
Reset for Channel 2 Heating 0.02 0 - 9.9 Repeats/minute
Rate for Channel 2 Heating 0 0 - 9.9 Minutes
Cycle Time for Channel 2 Heating 1 1 - 60 Seconds
Rate Band for Channel 2 Heating 0 0 - 7 Seconds
Channel 2 Proportional Band Cooling 40 0 - 50 Degrees C
Reset for Channel 2 Cooling 0.1 0 - 9.9 Repeats/minute
Rate for Channel 2 Cooling 0 0 - 9.9 Minutes
Cycle Time for Channel 2 Cooling 7 1 - 60 Seconds
Rate Band for Channel 2 Cooling 0 0 - 7 Seconds