Dehumidify Coil
This output operates the dehumidify coil for dehumidification.
Output is either Time Proportioning or On/Off
L11 Dehumidify On Percent dehumidify required to enable dehumidify device
L12 Dehumidify Off Percent humidity required to turn off dehumidify device
LEV 1 Selects the Drier Device when Input 2 is closed,
otherwise the Dehumidify Coil is selected.
Dehumidify Coil vs. Drier Logic (Input 2) When closed and when LEV 1 is set to Use Drier,
disables the dehumidify coil and uses the Drier device
instead.
Affected By: Default Value: Range:
Channel 2 Proportional Band Cooling 40 0 - 50 Degrees C
Reset for Channel 2 Cooling 0.1 0 - 9.9 Repeats/minute
Rate for Channel 2 Cooling 0 0 - 9.9 Minutes
Cycle Time for Channel 2 Cooling 7 1 - 60 Seconds
Rate Band for Channel 2 Cooling 0 0 - 7 Seconds