Owner`s manual

7
SimpliFire • SF-BI30-E, SF-BI36-E • 2040-900 Rev. G • 1/15
D. Location
Whenchoosingalocationforyourreplaceensurethat
thegeneralrulesarefollowed:
• Forbestresults,installoutofdirectsunlight.
• Powersupplyservicemustbeinstalledwithin
proximityofelectricreplacepriortonishingto
avoidreconstruction.
• SeeFigure3.Cforappliancedimensionsandto
determinelocationofapplianceinstallation.
E. Clearance to Combustibles
Minimum Clearance to Combustibles
Sides.......................0in.
Floor........................0in.
Top..........................0in.
Back........................0in.
Front.......................36in.
Mantels..........SeeFigure3.1
WARNING! Risk of Fire! Keepelectricalcords,drapery,
furnishings or other combustibles at least 3 ft. (0.9 m)
fromthefrontoftheelectricreplace.
F. Electrical Supply Circuit Requirements
Planthelocationoftheappliancesothatitwillhave
adequateelectricpower.A15AMP,120V/60hz.circuit
isrequired.Additionalappliancesonthesamecircuitas
thisappliancemayexceedthecurrentratingofthatcir-
cuit.Adedicatedcircuitisnotrequired,butispreferred
topreventcircuitbreakertripsorfusefailure.
ReferenceSection4.Eformorecompletedetailoncom-
pletingelectricalinstallation.
2 in.
2 in.
2 in.
6 in.
12 in.
Measurements from top surface
of the door front.
Figure3.1MinimumVerticalandMaximumHorizontalDimensionsofCombustibleMantels.