SimpliPhi Warranty

SimpliPhi Power, Inc. | 420 Bryant Circle | Ojai, CA 93023, USA | (805) 640-6700 | info@simpliphipower.com | SimpliPhiPower.com
| 4 |
Section 2.0 – SimpliPhi Power Guide for Operating
Parameters
Although SimpliPhi batteries are capable of performing at very high rates and depths of discharge within a
very wide temperature range, in order to achieve extended life cycles and to comply with the Warranty,
the following guidelines should be followed:
Table 1.0
Operating Parameters for 10 Year Warranty
Equivalent to 80% Retained Capacity 10,000 cycles 5,000 cycles 3,500 cycles
Discharge/Charge Rate
1,2
C/2
Depth of Discharge (DoD)
4
80% 90% 100%
Operating Temperature °F (°C) 32 to 110 (0 to 43) 32 to 120 (0 to 49) 32 to 120 (0 to 49)
Programming Settings for Ancillary Equipment
PHI Battery Voltage 24V 48V 24V 48V 24V 48V
Absorb / High Cut-Off Voltage (V)
3
28 56 28.8 57.6 28.8 57.6
Recharge / Low Cut-Off Voltage (V)
3
25.1 50.2 24.8 49.6 24 48
1
Continuous charge/discharge rate limitations vary per PHI battery model. See table 2 below
2
60A Discharge Rate (10 minutes maximum)
3
Levels are typically @ 25°C and may need adjusting at temperature extremes.
4
When performing rapid deep charge/discharge cycles, the battery should be allowed to "rest" 15 mins in between.
Table 2.0
Operating Limitations
Battery Model
PHI 2.7 PHI 3.5
Battery Voltage 24V 48V 24V 48V
Continuous Discharge Rate (A) 45 26 45 34
Continuous Charge Rate (A) 45 26 45 34