Note also that the quantity of PHI Batteries calculated from this sizing guide is the minimum requirement to
prevent over-discharge and over-charge from an instantaneous power perspective. The system may need more
PHI Batteries in the battery bank in order to meet the system’s energy requirement (the amount of power the
batteries must supply to the loads over time).
Refer to SimpliPhi’s online Battery Bank Sizing Estimator tool for assistance with sizing the PHI Battery Bank
according to connected loads and the desired number of days of autonomy:
https://simpliphipower.com/support/battery-bank-sizing-estimator/
.
CAUTION: Not all system discharge or charge characteristics can be mitigated via
programming. Under-sizing a PHI Battery bank relative to the system’s maximum discharge or
charge rate will destroy the PHI Batteries and Void the Warranty.
4.0 Program Settings for PHI Batteries
4.1 SkyBox Settings
Unlike most other equipment, the OutBack SkyBox has PHI battery-related settings pre-programmed into
versions 1.5.0 and later. Instead of programming custom settings into the equipment (as described in later sub-
sections of this Section 4.0 Program Settings for PHI Batteries), simply select “SimpliPhi” from the dropdown
menu on the SkyBox’s Battery Configuration screen in order to maintain the PHI Battery warranty:
Refer to this linked SkyBox: Commissioning with Energy Storage video for further instruction:
https://www.youtube.com/watch?v=twmI7_og-Dw
.
4.2 – Inverter Settings (Non-SkyBox)
In order to maintain the PHI Battery Warranty, it is critical to ensure that the appropriate settings are
programmed in all system components. The settings outlined in the following section maintain a maximum 80%
Depth of Discharge (DoD) for the PHI batteries, thereby optimizing the performance and life of the PHI batteries.
Not all OutBack equipment includes all the below listed settings. Settings that are not explicitly listed below do
not directly pertain to the PHI batteries. Refer to the relevant OutBack manual for more detailed information on
any one of the listed settings.
OutBack equipment networked together via the HUB and with a MATE3s system controller can be programmed
via the MATE3s (instead of directly in the inverter/charger and/or charge controller). Video instructions for