Technical approval

Page 212 of 291 of European Technical Assessment no. ETA-06/0106, issued on 2014-10-14
Table D37-5 E7/2.5 - Post to rigid support connection
4,0x35 4,0x60 4,0x35 4,0x60
f 23,4
f > 23,4
f 31,9
f > 31,9
f 43,6
f > 43,6
f 61,2
f > 61,2
f 148
f > 148
19,2 / ( f + 28 )
19,2 / ( f + 28 )
0,6
1,2
1,4
2,5
2,8
Connector nail according to ETA-04/0013:
Connector nail according to ETA-04/0013:
19,2 / ( f + 28 )
4,0x60
2,0
8 / f
Column to rigid support connection
Nailing 10+1 bolt
(bottom row of nails in vertical flap disregarded for R
1,k
)
1 angle bracket per connection
R
1,k
4,0x35
2 angle brackets per connection
Modified characteristic capacity per
connection (kN)
R
2,k
= R
3,k
4,0x60
4,0x35
2,2
R
1,k
R
2,k
= R
3,k
1,1
2,2
1,7
0,9
1,9
16,2 / f
19,2 / ( f + 28 )
I
Load
duration
P
3,3
3,7
4,6
1,1
1,4
1,6
1,8
L
M
S
0,7
0,8
11 / f
19,2 / ( f + 28 )
13 / f
19,2 / ( f + 28 )
10 / f
6,0
3,7
7,3
4,0
2,3
4,6
2,6
5,3
3,0
f in mm
Note: For R
1,k
for 1 angle bracket connection, if the purlin or column is prevented from rotation, consider the value as
the half of the one given for two brackets.
Requirement for the bolts see declaration under table D37-4