Technical approval

Page 240 of 291 of European Technical Assessment no. ETA-06/0106, issued on 2014-10-14
Table D43-2 ADR6090 - beam to rigid support connection 1 and 2 angle bracket
Beam to rigid support
connection
Nailing 5+1 bolt
(fig(D43-2B)
characteristic capacity per connection (kN)
1 angle bracket per
connection
2 angle bracket per
connection
R
1,k
R
1,k
Fastened on a
CNA4,0 x 40 and 4,0x60
CNA4,0 x 40 and 4,0x60
concrete structure
min of:
86,5 / ((f+22)xk
mod
)
35 / ((f+8)*k
mod
)
8,9
min of:
15,7
9,9 / k
mod
Leigth weight concrete
or masonry structure
min of:
75 / ((f+22)xk
mod
)
35 / ((f+8)*k
mod
)
8,3
min of:
14,5
9,1 / k
mod
for bolt: factor k
ax
(f+23) / 10
0,92
f in mm
For each bolt it´s needed to check: R
bolt,d,axial
≥ k
ax
x F