Index/Indice Concrete Connectors and Anchors BPS-LBPS............................ 13 FWANZ.................................. 14 MAB................................ 15–17 MASA.............................. 18–21 SB......................................... 22 SSTB..................................... 23 URFP.................................... 24 Holdowns and Tension Ties HD......................................... 25 HDQ8.................................... 26 HDU......................................
Connectors: Types of Nail Holes Conectores: Tipos de Agujeros de Clavo Round Redondo Triangular Hexagonal Hexágono Obround Alargado Diamond Diamante •• Purpose: To fasten a connector. •• Propósito: Para fijar un conector. •• Fill Requirements: Always fill, unless otherwise noted. •• Requisitos para Llenar: Llénelo siempre, salvo que se indique lo contrario. •• Purpose: To increase a connector’s strength or to achieve maximum strength.
Connectors: Types of Nail Holes Conectores: Tipos de Agujeros de Clavo •• Purpose: Installed into the joist and header, to distribute the load through two points on each joist nail for greater strength. Must use full-length nail unless 2 1/2” nail approved by Designer. •• Fill Requirements: Always fill. Double-Shear Nailing Clavado de Doble Penetración •• Propósito: Instalado en la vigueta y la cabecera, para distribuir la carga a través de dos puntos en cada clavo de vigueta para mayor resistencia.
Connectors: Types of Nail Holes Conectores: Tipos de Agujeros de Clavo •• Purpose: To guide the nail into the joist and header at a 45° angle. •• Fill Requirements: Always fill. Dome Nailing Clavado con Cúpula •• Propósito: Con este dispositivo se guían el clavo en lavigueta y la viga cabezal en ángulo de 45°. •• Requisitos para Llenar: Llénelo siempre. •• Purpose: To use when wood splitting may occur, and to speed installation. •• Fill Requirements: Always fill.
Fasteners/Clavos 0.162" x 3 1/2" (16d common) 0.162" x 2 1/2" (N16) 0.148" x 3 1/4" (16d sinker) 0.148" x 3" (10d common) " Same uses " Mismo uso " " " " 3x wood nailers. NOT for double-shear nailing unless approved by Designer. " " " Straps, heavy hangers, plated truss and SCL connectors. Cintas, soporte de viga pesadas, para cerchas y madera composito. 6 Para madera de 3". NO para clavado de double penetración salvo que así lo apruebe el diseñador. Straps, hangers, header fastening.
Fasteners/Clavos 0.148" x 1 1/2" 0.148" x 2 1/2" (N10) 0.131" x 2 1/2" (8d common) 0.131" x 1 1/2" (N8) " " " " Light-duty framing anchors and some rafter ties. 2x joist nailing. Caution: Load reduction if used as header nails. Galvanized nail shown. Clavado de vigas 2x. Cuidado: Reduce la capacidad si se usa en la viga cabezal. Se muestra un clavo galvanizado. " " Galvanized nail shown. Collated 3x wood nailers. NOT for double-shear nailing unless approved by Designer. Rafter ties.
Fasteners/Clavos Power-driven collated nails can be used only if: 1. Correct diameter and length 2. Correct quantity is installed 3. The power tool has a hole location feature (finds the hole) 4. Nails are not overdriven Sólo se pueden utilizar clavos estructurales para pistola si: 1. Diámetro y largo correctos 2. La cantidad correcta está instalada 3. L a herramienta eléctrica tiene una función de ubicación de orificio (encuentra el orificio) Do Not Overdrive Nails.
Fasteners/Clavos Some connectors install with the 1/4" Strong-Drive® SDS Heavy-Duty Connector screw 1. Install with 3⁄8" hex socket or nut driver 2. Predrilling generally not required 3. Do not substitute with lag screws Algunos conectores se instalan con el ¼" Strong-Drive® SDS Heavy-Duty Connector screw. 1. Instalar con un destornillador de casquillo hexagonal o de tuercas de 3⁄8" 2. Generalmente no es necesario efectuar perforaciones previas 3.
General Connector Installation Instalación de Conectores en General Top Flange Hangers Soportes Con Ala Superior Flush Framing Hanger over-spread Hanger not plumb Soporte demasiado abierto Soporte fuera de plomo Wood Nailers Listones Clavadores De Madera Correct attachment Nailer too wide Montaje correcto Listón clavador muy ancho Nailer too narrow Nailer too thin or wrong hanger for the application Listón clavador muy estrecho Clavadora demasiado delgada o soporte incorrecto para la aplicació
General Connector Installation Instalación de Conectores en General Prevent Rotation/Evitar La Rotación D 60% of D min.
General Connector Installation Instalación de Conectores en General Double-Shear Nailing Clavado De Doble Penetración Must use full-length nail unless 2 1/2" nail approved by Designer. Debe usar un clavo de largo completo a menos que un clavo de 2 1/2" esté aprobado por el diseñador. Shorter nails may not be used as double-shear nails. No se pueden utilizar clavos más cortos como clavos de doble penetración. No gaps larger than 1/8". No hay espacios mayores a 1/8".
Concrete Connectors and Anchors BPS-LBPS 1 2 3 13
FWANZ 0.
MAB — Block/Bloque 1 0.
MAB — Concrete/Concreto 1 2 3 4 1 2 3 4 5 16
MAB — Concrete/Concreto 6 7 0.
MASA Forming Encofrado or/ó (2) Duplex nails / Clavo duplex or/ó (1) 0.148" x 3" 1 0.131" x 21/2" 0.
MASA Connector Conector 4 0.148" x 11/2" 5 Alternative 1 Opción 1 Reduced loads apply; check with Designer. Se aplican cargas reducidas; consulte al diseñador. Alternative 2 Opción 2 Blocking required attached to sill with A35Z (not shown) or per Designer. Se debe adjuntar un bloqueo al larguero con A35Z (no se muestra) o según indicaciones del diseñador. Reduced loads apply; check with Designer before nailing over sheathing.
MASA Brick-Ledge Installation Instalación Sobre Cornisa de Ladrillos (2) Duplex nails / Clavo duplex 1 2x4 plate 3½" 2 3 20
MASA Inside-the-Mudsill Installation Instalación en Solera (2) Duplex nails / Clavo duplex 1 2 3 Embedment line (top of concrete) Línea de empotramiento (parte superior del concreto) MASAP similar 21
SB AnchorMate® Embedment line (top of concrete) 1 24 450 34 450 24 24 Línea de empotramiento (parte superior del concreto) Install a minimum 45° from either edge. Instalar a mínimo 45° de cada cara.
SSTB AnchorMate® Embedment line Embedment line (top of concrete) 1 (top of concrete) Línea de empotramiento Líneasuperior de empotramiento (parte del concreto) (parte superior del concreto) 24 450 34 450 24 24 ABS Anchor Bolt Stabilizer (optional) Install 45° from either edge. Instalar 45° de cada cara.
URFP 1 S2.5 S2.5 S2.5 FOR 1/2" FOR SILL BOLT 5/8" REPLACE SILL BOLT MENT, REPLACE FILL ROUND MENT, FILL ALL HOLES SIMPSON HOLES Strong-T ie® Same installation for FRFP 2 3 4 5 6 S3 S3 S3 S3 S3 1/4" x 3" SDS Heavy-Duty Connector Screw (included) 24 1/2" x 4" Titen HD®. If using adhesive anchor, see pp. 106-107.
Holdowns and Tension Ties HD 1 Model No./ N.º de Modelo Bolt Diameter/ Diámetro del Perno Torneado HD3B HD5B HD7B HD9B HD12 HD19 5⁄8" 3⁄4" 3⁄4" 7⁄8" 1" 1" 2 3 4 Bolts shall be installed with the nut and washer on the opposite side of the holdown. Se deben instalar los pernos con la tuerca y la arandela en lado opuesto del amarre. 5 Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter.
HDQ8 1 2 3 Square washer required (included). Se requiere una arandela cuadrada (incluida). Use 3⁄8" driver. Use un destornillador de 3⁄8".
HDU 1 2 3 Use 3⁄8" driver. Use un destornillador de 3⁄8”.
HTT HTT4 HTT5 1 2 0.
LSTHD/STHD StrapMate® 1 Embedment line (top of concrete) Línea de empotramiento (parte superior del concreto) 2 Strap may be bent down and back up one time only. La abrazadera se puede doblar hacia abajo y hacia arriba sólo una vez. 16d Sinker 0.
Bases and Caps ABA 1 2 3 If using an adhesive anchor, see pages 106–107 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 106–107. 4 0.162" x 3 1⁄2" — ABA46, ABA46R, ABA66, ABA66R 0.
ABU — Nails/Clavos 1 2 3 4 0.162" x 3 1/2" 5 If using an adhesive anchor, see pages 106–107 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 106–107.
ABU — Bolts/Pernos 1 2 3 4 If using an adhesive anchor, see pages 106–107 for instructions. 5 32 Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 106–107.
ABU — Bolts/Pernos 6 7 8 Bolt Diameter: 1/2" Length: ABU44/ABU46 = 4 1/2" ABU66 = 6 1/2" Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter. Perno Torneado Diámetro: 1/2" Largo: ABU44/ABU46 = 4 1/2" ABU66 = 6 1/2" Los orificios para los pernos deben ser al menos 1∕32" y como máximo 1∕16" más grandes que el diámetro del perno.
ABW 1 2 3 0.
BC 1 2 0.
BCS2-2/4 1 2 0.
BC40 1 0.
CB — Bolts/Pernos 1 3" min. 3" min. 2 3 38 3" side cover (min.) 3" min. Cubierta lateral 3" min. de 3" (mín.
CB 3" side cover (min.) Cubierta lateral de 3" (mín.) 3" min. 3" min. 4 Model No. / N.º de Modelo Bolt Size / Tamaño del Perno CB44 CB46 CB48 CB64 CB66 CB68 CB86 CB88 CB1010 CB1012 CB1212 5⁄8" x 4 1⁄2" 5⁄8" x 4 1⁄2" 5⁄8" x 4 1⁄2" 5⁄8" x 6 1⁄2" 5⁄8" x 6 1⁄2" 5⁄8" x 6 1⁄2" 3⁄4" x 8 1⁄2" 3⁄4" x 8 1⁄2" 3⁄4" x 10 1⁄2" 3⁄4" x 10 1⁄2" 3⁄4" x 11 1⁄2" 5 Bolt Perno Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter.
CBSQ 3" min. 1 3" min. 2 4 1⁄4" x 2" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw 40 3 5 Use 3⁄8" driver. Use un destornillador de 3⁄8".
CC 1 2 3 4 Bolt Perno 5 Bolt Size Beam or Column Width Tamaño del Perno Torneado Ancho de Dintel o de Columna Diameter Diámetro Length Longitud 3 1⁄8" 5⁄8" 4 1⁄2" 3 1⁄2" 5⁄8" 4 1⁄2" 5 1⁄8" 3⁄4" 6 1⁄2" 5 1⁄2" 5⁄8" 6 1⁄2" 6 3⁄4" 3⁄4" 8" 7" 3⁄4" 8" 7 1⁄2" 3⁄4" 8 1⁄2" 8 3⁄4" 3⁄4" 10" 9 1⁄2" 3⁄4" 10 1⁄2" 6 Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter.
CCQ 1 2 3 Use 3⁄8" driver. Use un destornillador de 3⁄8".
CPTZ 1 2 3 4 5 6 7 8 If using an adhesive anchor, see pages 106–107 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 106–107.
LCE4 4x4 Beam Viga 4x4 Post Poste 1 0.
PB 1 2 0.
PCZ/EPCZ 1 2 3 4 1 0.
PPBZ Mark drill holes. Marque los agujeros a taladrar. Drill 1/4"-diameter hole 1/2" deeper than Titen®. 1" min. 1" min. 6" min. 1 Perdore un afujero de 1/4" de diámetro a una profundidad de 1/2" mayor que el Titen®. 2 3 5 4 6 For installation in concrete, use Titen® 2 masonry screw 1/4" x 1 1/4". Para instalaciones en concreto, utilice Titen de 1/4" x 1 1/4". 0.
RPBZ 1 2 3½" side cover (min.) Cubierta lateral de 3½" 3½" Side Cover (min.) (mín.) 3 S1.5 S1.5 S1.5 4 S1.
Solid Sawn Joist Hangers HUS 1 2 3 4 0.
LSSJ 1 2 3 0.
LRU 1 33 2 44 0.
LSSR 1 45˚ max.
LSSR 4 Acute side nailing Joist nails on obtuse side 5 6 7 Fasteners Model No. Face (in.) Joist (in.) 0.148 x 2 1/2 0.148 x 1 1/2 0.162 x 2 1/2 0.162 x 2 1/2 LSSR1.81Z LSSR2.1Z LSSR2.37Z LSSR2.
LUCZ Header Viga Cabezal Joist Viga 1 0.148" x 1 1/2" 0.
Upgrade your coiled strap. Our new high-performance CSHP coiled strap is easy to install with a standard pneumatic framing nailer. Visit go.strongtie.com/cshp or call (800) 999-5099.
LUS 1 2 3 56
LUS 4 0.148" x 3" for single 2x. 0.148" x 3" para un solo 2x. 5 0.162" x 3 1/2" for all others. 0.162" x 3½" para los demás.
SUR/L 1 0.148" x 1½" 0.162" x 3½" 2 0.
SUR/L 4 0.162" x 3 1/2" 5 0.148" x 1 1/2" 0.
VPA 0.148" x 3" 1 0.148" x 1½" Adjust to required Required Pitch pitch. Inclinación Inclinación Requerida requerida. 0.148" x 3" 2 0.
VPA 0.148" x 1½" 4 0.
Engineered Wood and Structural Composite Lumber Connectors ITS The Strong-Grip™ seat allows the I-joist to “snap” in securely — no joist nails needed. El asiento Strong-Grip™ permite que la viga ‘I’ “encaje” con firmeza; no se necesitan clavos para vigas. 90° 1 2 0.148" 10dx 3" 3 0.
ITS 0.148" 10dx 3" 4 5 No nails required in joist. No es necesario clavar clavos en la viga.
IUS The Strong-Grip™ seat allows the I-joist to “snap” in securely — no joist nails needed. El asiento Strong-Grip™ permite que la viga en ‘I’ “encaje” con firmeza; no se necesitan clavos para vigas. 1 2 3 4 0.
IUS 5 6 No nails required in joist. No es necesario clavar clavos en la viga.
Plated Truss Connectors DTC 1 Install nail in center of slot. Instale el clavo en el centro de la ranura. 2 Truss nails not driven flush. Truss nails not driven flush Los clavos de la cercha no deberían Los clavos la asentarse contra elde conector cercha no deberían asentarse contra el conector. 0.
STC 1 0.131" x 1 1/2" 2 Gap Install nail in center of slot. Instale el clavo en el centro de la ranura. Truss nails not driven flush. Los clavos de la cercha no deberían asentarse contra el conector.
HTU 1 0.162" x 3 1/2" 0.148" x 1 1/2" 0.162" x 3 1/2" 2 0.148" x 3" for double 2x joists 0.162" x 3 1/2" 0.148" x 1 1/2" 3 5 4 0.148" x 1 1/2" For double truss, use 0.148" x 3" nails into trusses. 68 Para cerchas dobles, use clavos 10d x 3" insertados en las cerchas.
TSBR 0.
THA Installation on Solid Header Instalación Sobre Viga Cabezal Sólida Top-Mount Condition / Condición de Montaje Superior 2 1 Install joist nails both sides. Instale clavos para vigas a ambos lados. Face-Mount Condition / Condición de Montaje Sobre Cara Install joist nails both sides. 2 1 0.148" x 1 1/2" 0.148" x 3" 0.162" x 3 1/2" 70 Instale clavos para vigas a ambos lados.
THA Installation on Solid Header Instalación Sobre Viga Cabezal Sólida Model Modelo Top and Face Encima and Cara Joist Vigueta THA29 THA213 THA413 THA218 THA218-2 THA418 THA422 THA222-2 THA422-2 THA426 (16) 0.148" x 3" (4) 0.148" x 3" (14) 0.148" x 3" (4) 0.148" x 3" (18) 0.148" x 3" (4) 0.148" x 3" (22) 0.162" x 3 1/2" (6) 0.162" x 3 1/2" (30) 0.162" x 3 1/2" (6) 0.162" x 3 1/2" Installation on Truss Instalación Sobre Cercha Nail Location Ubicación de Los Clavos Qty/Nail Cant.
THJA 2 1 0.162" x 3 1/2" 3 0.162" x 3 1/2" 4 0.148" x 1 1/2" 0.148" x 1 1/2" Left hand hip installation si Left-hand hip installation similar. Similar a la instalación ‘izquierda’ de cumbre. 0.148" x 1½" 0.
THJU 1 2 3 4 0.
Masonry Connectors HETA/META 1 0.148" x 1 1/2" Quantity per Designer. Cantidad según indicaciones del diseñador.
HETA/META 4 Moisture barrier not shown (typ.) La barrera contra la humedad no se muestra (típ.
LGT Fill holes with Titen® 2 masonry screws. Llene los orificios con tornillos para mampostería Titen®. 1 LGT2 shown. LGT3 and LGT4 similar. For wood-to-wood connections using the LGT, visit strongtie.com. Se muestra LGT2. Similar a LGT3 y LGT4. Para conexiones de madera a madera usando el LGT, visite strongtie.com. 2 3⁄16" Drill Bit Broca de 3⁄16" 3 Compressed Air Aire Comprimido Titen 2 Masonry Screw / Tornillo para mampostería (1/4" x 2 1/4") For installation in concrete, use Titen 2 1/4" x 1 3/4".
LGT 4 LGT2 shown. For installation of LGT3/LGT4, see strongtie.com. Se muestra LGT2. Para la instalación de LGT3/ LGT4, consulte strongtie.com. 5 6 0.
VGT 1 If using an adhesive anchor, see pages 106–107 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de las páginas 106–107. Use 3⁄8" driver. Use un destornillador de 3⁄8".
VGT 2 3 79
Straps and Ties A35 1 1 2 2 3 3 0.
CSHP 1 See strongtie.com/cshp for framing nailer use. This side Up Consulte strongtie.com/cshp para el uso de clavadoras para entramados. 3 This side Up 2 Lumber Species / Especies de Madera Douglas Fir-Larch / Southern Pine Spruce-Pine-Fir / Hem-Fir Model / End Cut Total End Cut Total Modelo Length / Length / Fasteners / Length / Length / Fasteners / Largo del Largo a Total de Largo del Largo a Total de Extremo Cortar Clavos Extremo Cortar Clavors 10" Clear Span (16) (Luz) + 20" 0.
CS/CMST14 CS14 Shown Mostrado 1 Quantity per Designer. Cantidad según indicaciones del diseñador. 0.131" x 2 1/2" 2 0.148" x 2 1/2" Sheathing not shown for clarity. No muestra el revestimento para mayor claridad. CMST requires minimum (2) 2x studs CMST requiere puntales de (2) 2x como mínimo Provide min. 1⅝" end distance for CS and CMST Dejar al menos 1⅝" y distancia para CS y CMST Equal number of specified nails in each end Igual cantidad de clavos especificados en cada extremo 82 0.
CS/CMST14 Sheathing not shown for clarity. Across joists. Sobre varias viguetas. No muestra el revestimento para mayor claridad. Lumber Species / Especies de Madera Douglas Fir-Larch / Southern Pine Spruce-Pine-Fir / Hem-Fir Model / End Cut Total End Cut Total Modelo Length / Length / Fasteners / Length / Length / Fasteners / Largo del Largo a Total de Largo del Largo a Total de Extremo Cortar Clavos Extremo Cortar Clavors CS14 CS14-R CS16 CS16-R CS20 CS20-R 16" Clear Span (30) (Luz) + 32" 0.
H1 — Rafter/Cabrio 0.131" x 2 1/2" 1 Rafter Cabrio Plate Placas 0.131" x 1 1/2" 2 0.131" x 1 1/2" 0.131" x 1 1/2" 0.
H1 — Truss/Viga 1 0.131" x 2 1/2" Truss Viga Plate Placas 0.131" x 1 1/2" 2 0.131"x1 1/2" 0.131" x 2 1/2" 3 0.
H2.5A 1 Rafter Cabrio 2 0.131" x 2 1/2" Truss Viga 3 Installations in Pairs Both connectors shall be same model. Instalaciones en Pares Ambos conectores deben ser del mismo modelo. 86 Wall top plate Install diagonally across from each Placa superior other for minimum de la pared 2x truss. Plan View Vista de Planta Instale diagonalmente uno respecto del otro para dejar una cercha de 2x como mínimo.
H2.5T 1 Rafter Cabrio 2 0.131" x 2 1/2" 3½" Truss Viga 3 Products can be on the same side of the wall provided they are configured as shown. Los productos se pueden instala a ambos lados de la pared siempre que se configuren como se muestra.
H10A — Rafter/Cabrio 1 0.
H10A — Blocking/Entramado 1 2 0.
LS 1a 1b 2a 2b 3a 3b 0.
LSTA 1 2 3 Hanger not shown for clarity. El soporte colgante no se muestra para ofrecer mayor claridad. 0.
LTP4/LTP5 0.131" x 1 1/2" Fasteners: LTP4 No sheathing: 0.131" x 1 1/2" Over sheathing (3⁄8" thick max.): 0.131" x 2 1/2" 0.131" x 2 1/2" LTP5 No sheathing: 0.131" x 1 1/2" Over sheathing (1⁄2" thick max.): 0.131" x 2 1/2" Sujetadores: LTP4 Sin relleno: 0.131" x 1 1/2" Sobre relleno (3⁄8" de espesor máx.): 0.131" x 2 1/2" LTP5 Sin relleno: 0.131" x 1 1/2" Sobre relleno (1/2" de espesor máx.): 0.
RBC 1 2 0.
MST 1 2 No Sheathing / Sin Relleno 0.
MST 1 2 With Sheathing / Con Relleno 3 End length Largo del extremo Clear span LUZ 0.
RSP 1 0.
SP 1 0.
SSP Installation on Mudsill Instalación sobre Durmientes 0.
TSP 1 2 3 0.
Deck DTT1Z Connectors DTT1Z 1 2 3 Strong-Drive® SDWH TIMBER-HEX HDG Screw 100 3" embedment 3" empotramiento #9 x 1 1/2" Strong-Drive SD CONNECTOR Screw
DTT2Z 1 2" 2" 2 Threaded Rod 3 1/4" x 1 1/2" Strong-Drive® SDS HEAVY-DUTY CONNECTOR Screw 101
Miscellaneous HSS Bend flanges one time only. Doble las alas una vez. 1 2 3 4 Use 3/8" driver. 102 Use un destornillador de 3/8".
PSPN 1 2 0.
TWB 1 2 0.131" x 2 1/2" at studs / en los montantes 0.162" x 3 1/2" at plates / 3 en las soleras 4 Cut 5/8" kerf. Corte un corte de 5/8".
TWB (2) 0.162" x 3 1/2" 5 6 7 8 0.131" x 2 1/2" (2) 0.
Anchoring and Fastening Systems for Concrete and Masonry Adhesive Anchoring / Anclaje Adhesivo (AT-XP®, SET-3G®, and SET-XP®) 1 Compressed air (80 psi min.), 4 seconds (min.) — AT-XP, SET-XP 2 seconds (min.) — SET-3G Aire comprimido (80 psi mín.), 4 segundos (mín.) — AT-XP, SET-XP 2 segundos (mín.) — SET-3G 2 Nylon brush 4 cycles (min.) — AT-XP, SET-XP Wire brush 2 seconds (min.) — SET-3G Cepillo de nylon 4 ciclos (mín.) — AT-XP, SET-XP Cepillo de alambre 2 segundos (mín.
Adhesive Anchoring Anclaje Adhesivo Compressed air (80 psi min.), 4 seconds (min.) — AT-XP, SET-XP 2 seconds (min.) — SET-3G Aire comprimido (80 psi mín.), 4 segundos (mín.) — AT-XP, SET-XP 2 segundos (mín.) — SET-3G 4 Dispense until mixed properly (uniform color). Suministre hasta que esté bien mezclado (color uniforme).
Titen HD ® 1 2 Washer or bearing plate as required by building code. Arandela o disco de presión según lo requiera el código de construcción. 3 108 1/2" min.
Fastening Systems Strong-Drive® SDWC Truss Screw Note: SDWC Truss screws can also be installed using the Quik Stik™ Rafter and Truss Fastening System. 1 Metal installation guide tool Herramienta guía de instalación de metal Installation guide channel Canal de guía de instalación 2 Metal installation guide tool Herramienta guía de instalación de metal Installation guide channel Canal de guía de instalación Optimal 22o o 10o 0 30 o 3 4 3" ½" max.
Strong-Drive® SDWF Floor-to-Floor Screw 1 2 2" min.
Strong-Drive® SDWF Floor-to-Floor Screw SDWF depth guide (included) 6 Outs Vista d ide Wall Vie el muro w desde afuera 7 Insid Vista d e Wall Vie w el mur o desd e afue ra 3¼ " 5" SS W (U (U.S F .S. .PPate DDW atenntt 8 F 8,2 ,2776 6,3 ,32 233)) 3½" TUW TUW (U.S. Patent 8,276,323) (U.S.