Every day we work hard to earn your business, blending the talents of our people with the quality of our products and services to exceed your expectations. This is our INSTALLER’S POCKET GUIDE pledge to you. Nos esforzamos fuerte diariamente combinando el talento de nuestro GUÍA DE BOLSILLO PARA EL INSTALADOR personal con la calidad de nuestros productos y servicios excediendo sus expectativas para tenerlo a usted como cliente. Este es nuestro compromiso para con usted. S-INSTALL09 800-999-5099 www.
Simpson Strong-Tie QUESTIONS? ¿PREGUNTAS? (800) 999-5099 This guide is intended to provide a quick reference tool to aid in the correct installation of Simpson Strong-Tie® products. It is important that users follow any installation guidelines specified by the Designer and refer to the current Simpson Strong-Tie Wood Construction Connectors catalog for other important installation information. This guide is not intended for use as a design tool by Designers.
Index/Indice A35 ............................. 17 H1 .......................... 40-41 LS ............................... 68 SP ............................... 92 AB .......................... 18-19 H2.5A .......................... 42 LSSU........................... 69 SP4 ............................. 93 ABA ............................. 20 H2.5T .......................... 43 LSTA ........................... 70 SSP ............................. 94 ABU........................ 21-23 H10 .........
Connectors: Types of Nail Holes Conectores: Tipos de Agujeros de Clavo • Purpose: To fasten a connector. • Fill Requirements: Always fill, unless otherwise noted. ROUND REDONDO TRIANGULAR • Propósito: Para fijar un conector. • Requisitos para Llenar: Llénelo siempre, salvo que se indique lo contrario. • Purpose: To increase a connector’s strength or to achieve MAX strength. • Fill Requirements: When the Designer specifies “Max” nailing.
Connectors: Types of Nail Holes Conectores: Tipos de Agujeros de Clavo DOUBLE-SHEAR NAILING CLAVADO DE DOBLE PENETRACIÓN • Purpose: Installed into the joist and header, distributing the load through two points on each joist nail for greater strength. Must use full length nail. • Fill Requirements: Always fill, and make sure you use the right nail. • Propósito: Para lograr mayor fuerza, los clavos penetran a la vigueta y la viga cabezal, así distribuyendo la carga entre las dos puntas de cada clavo.
Fasteners/Clavos 16d 16dx2 1⁄2" 16d Sinker 10d 10dx1 1⁄2" 8d 8dx1 1⁄2" Same uses Mismo uso (0.162") (0.162") 16d Common Straps, heavy hangers, plated truss and SCL connectors. 10 16d Común Cintas, soporte de viga pesadas, para cerchas y madera composito. 16dx2¹⁄₂" 3x Wood nailers. NOT for double shear nailing unless approved by Designer. 16dx2¹⁄₂" Para madera de 3". NO para clavado de double penetración salvo que así lo apruebe el diseñador. (0.148") (0.
Fasteners/Clavos Some connectors install with the Simpson Strong-Tie® Strong-Drive® (SDS) ¹⁄₄" structural wood screw. 1. Install with ³⁄₈" hex socket or nut driver 2. Pre-drilling generally not required 3. Do not substitute with lag screws Framing nail-gun nails can only be used if: 1. Correct diameter and length 2. Correct quantity is installed 3. Driven with a hole location tool (finds the hole) or by hand NOTE: .121 may NOT be used to replace 10d or 16d nails.
General Connector Installation Instalación de Conectores en General TOP FLANGE HANGERS / SOPORTES CON ALA SUPERIOR PREVENT ROTATION / EVITAR LA ROTACIÓN Shorter hanger with no web stiffener results in rotation Un soporte colgante más corto sin de entramado permitirá la rotación Hanger over-spread Soporte demasiado abierto Hanger not plumb Soporte fuera de plomo TOE-NAILING / CLAVADO EN DIAGONAL Do not toe nail I-joists before installing top flange or face mount hangers No clave en ángulo las viguetas ‘I
General Connector Installation Instalación de Conectores en General A35 ITS/IUS HANGERS / SOPORTES DE ITS/IUS 1 DO NOT make your own holes DO NOT nail bottom chord NO haga otros orificios para los clavos NO clave en la viga inferior 1 2 2 DOUBLE SHEAR NAILING CLAVADO DE DOBLE PENETRACIÓN Double-shear nailing must use full length 10d or 16d common nails Al trabajar con clavado de doble penetración, se deben emplear clavos comunes 10d o 16d de longitud normal 3 Shorter nails may not be used as double-
AB AB 1 5 2 6 3 If using an adhesive anchor, see page 24 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de la página 24. 18 7 4 10d (0.
ABA ABU – Nails/Clavos 1 1 2 2 3 3 4 If using an adhesive anchor, see page 24 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de la página 24. 4 16d (0.162" x 3¹⁄₂") – ABA46, ABA46R, ABA66, ABA66R 10d (0.148" x 3") – ABA44, ABA44R 20 5 If using an adhesive anchor, see page 24 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de la página 24. 6 16d (0.
ABU – Machine Bolts/Pernos ABU – Machine Bolts/Pernos 1 2 Machine Bolt Diameter: 1⁄2" Length: ABU44/ABU46 = 4 1⁄2" ABU66 = 6 1⁄2" 3 4 5 If using an adhesive anchor, see page 24 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de la página 24. 22 6 7 Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter.
Adhesive Anchoring Anclaje Adhesivo Compressed air (80 psi min.), 4 seconds (min.) Aire comprimido (80 psi mín.), 4 segundos (mín.) Compressed air (80 psi min.), 4 seconds (min.) Aire comprimido (80 psi mín.), 4 segundos (mín.) 1 4 5 Dispense until uniform color Aplique hasta lograr un color uniforme Nylon brush 4 cycles (min.) Cepillo de nailon 4 ciclos (mín.
BC BCS2-2/4 1 2 1 2 3 3 10d (0.148" x 3") 16d (0.
BC40 BPS-LBPS 1 1 2 2 16d (0.
CB – Machine Bolts/Pernos CB – Machine Bolts/Pernos 4 1 Machine Bolt Perno 2 3" Side cover (min.) 3" Side cover (min.) Cubierta lateral de 3" (mín.) Cubierta lateral de 3" (mín.) 3 30 Model No./ N.
CBQ CBSQ 1 1 2 2 3 3 3" min. 3" min. 3" min. 3" min.
CC – Machine Bolts/Pernos CCQ 1 1 2 2 3 4 3 5 Machine Bolt / Perno Machine Bolt Size Beam or Column Width Tamaño del Perno Torneado Ancho de Dintel Diameter Length o de Columna Diámetro Longitud 34 1 3 ⁄8" 5 3 1⁄2" 5 5 1⁄8" 3 1 5 ⁄2" 5 6 3⁄4" 3 7" 3 1 7 ⁄2" 3 8 3⁄4" 3 9 1⁄2" 3 ⁄8" 4 ⁄2" ⁄8" 4 1⁄2" ⁄4" 6 1⁄2" ⁄8" 6 1⁄2" ⁄4" 8" ⁄4" 8" ⁄4" 8 ⁄2" 4 1 1 ⁄4" 10" ⁄4" 10 1⁄2" 6 Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter.
CS/CMST14 CS/CMST14 CS14 Shown Mostrado Across Joists Sobre Varias Viguetas 1 See chart for nail selection Consulte la tabla para seleccionar los clavos Lumber Species / Especies de Madera Douglas Fir-Larch/Southern Pine Spruce-Pine-Fir/HemFir 2 8d (0.131" x 2¹⁄₂") 10d (0.148" x 3") ls re nai he No uired a q re cesit í ne qu No vos a cla 16d (0.162" x 3¹⁄₂") (CMST requires minimum 2-2x studs) (CMST requiere puntales de 2-2x como mínimo) Provide min.
DTC GBC 1 1 8d x 1¹⁄₂" (0.131" x 1¹⁄₂") 8d x 2 1⁄2" Install nail in center of slot Instale el clavo en el centro de la ranura 8d (0.131" x 2¹⁄₂") 2 Truss nails not driven flush Los clavos de la cercha no deberían asentarse contra el conector 38 8d (0.
H1 – Rafter/Cabrio H1 – Truss/Viga 1 1 8d x 2 1⁄2" 8d x 2 ⁄2" 1 Plate Rafter Placas Cabrio Plate Truss Placas Viga 2 2 8d x 1 1⁄2" 3 8d x 1 1⁄2" 8d x 1 1⁄2" 8dx1¹⁄₂" (0.131" x 1¹⁄₂") 3 8d x 1¹⁄₂" (0.131" x 1¹⁄₂") 8d x 1 1⁄2" 8d (0.131" x 2¹⁄₂") 4 40 H1 Reversed H1 Invertido 8d (0.
H2.5A H2.5T 1 1 Rafter Cabrio Rafter Cabrio 2 2 8d (0.131" x 2¹⁄₂") 8d (0.131" x 2¹⁄₂") Truss Viga Installations in Pairs Both connectors shall be same model. Instalaciones en Pares Ambos conectores deben ser del mismo modelo. 42 Truss Viga 3 3 Wall Top Plate Placa superior de la pared Install diagonally across from each other for minimum 2x truss. Instale diagonalmente uno respecto del otro para dejar una cercha de 2x como mínimo.
H10 – Rafter/Cabrio H10 – Blocking/Entramado 1 1 8d x 1¹⁄₂" (0.131" x 1¹⁄₂") 8d x 1¹⁄₂" (0.
HDA HDA – Machine Bolts/Pernos ⁵⁄₈-1" 1 5 4 2 Machine Bolt / Perno 3 Model No./ N.º de Modelo HD2A 5 HD5A 3 ⁄8" ⁄4" HD6A 7 HD8A 7 HD10A 7 HD14A 46 Machine Bolt Diameter/ Diámetro del Perno Torneado ⁄8" ⁄8" ⁄8" 1" Machine bolts should be at least 1" longer than wood member thickness. Bolt holes must be a minimum of 1⁄32" and a maximum of 1⁄16" larger than bolt diameter. Los pernos torneados deben ser al menos 1" más largos que el espesor de los miembros de madera.
HDQ8 HDU 1 1 2 2 3 3 Square washer required (included) Se requiere una arandela cuadrada (incluida) Use 3⁄8" driver Use un destornillador de 3⁄8" 48 Use 3⁄8" driver Use un destornillador de 3⁄8" SDS ¹⁄₄" x 3" SDS ¹⁄₄" x 2¹⁄₂" (Included / Incluida) (Included / Incluida) 49
HETA HETA 4 1 2 10d x 1¹⁄₂" (0.
HPAHD22 1a HPAHD22 Nailed to block on form Clavado al bloque en forma 3a or / ó StrapMate® strap holder (SM1) 1b Strap may be bent down and back up one time only La abrazadera se puede doblar hacia abajo y hacia arriba sólo una vez 2 Attached with StrapMate® strap holder Fijar con sujetador de abrazadera StrapMate® Reduced loads apply. Check with Designer before nailing over sheathing 16d (0.162" x 3¹⁄₂") or / ó 3b Se aplican cargas reducidas.
HSS HSS Bend flanges one time only Doble las alas una vez 3 SDS ¹⁄₄" x 1¹⁄₂" 1 Use 3⁄8" driver Use un destornillador de 3⁄8" 2 54 4 55
HTT HTU HTT4 HTT5 HTT16 HTT22 1 16d 1 2 2 10d x 1¹⁄₂" (0.148" x 1¹⁄₂") 16d 3 16d x 2¹⁄₂" (0.162" x 2¹⁄₂") 3 10d (0.148" x 3") 10d x 1¹⁄₂" 10d (0.148" x 3") For double 2x joists 16d (0.
HUS HUS 1 3 4 2 16d (0.
ITS ITS The Strong-Grip™ seat allows the I-joist to “snap” in securely – no joist nails needed. El asiento Strong-Grip™ permite que la viga ‘I’ “encaje” con firmeza; no se necesitan clavos para vigas. 4 10d 90° 5 2 1 10d See pages 14-15 for more information. 6 Vea la página 14-15 para más información. 3 No nails required in joist 7 No es necesario clavar clavos en la viga 10d (0.
ITT ITT 10d 90° 1 2 6 5 10d 10dx1¹⁄₂" 4 3 7 8 See pages 14-15 for more information. Vea la página 14-15 para más información. 62 10d (0.148" x 3") On top and face by header Encima y en la cara de la viga cabezal 10d x 1¹⁄₂" (0.
IUS IUS The Strong-Grip™ seat allows the I-joist to “snap” in securely – no joist nails needed. El asiento Strong-Grip™ permite que la viga en ‘I’ “encaje” con firmeza; no se necesitan clavos para vigas. 5 1 2 6 3 7 4 See pages 14-15 for more information. Vea la página 14-15 para más información. No nails required in joist No es necesario clavar clavos en la viga 64 10d (0.
LGT2 LGT2 Fill 1 holes with 4 ® Titen masonry screws Llene los orificios con tornillos para mampostería Titen® 2 5 3 3 ⁄16" Drill bit Broca de 3⁄16" 6 Compressed Air / Aire comprimido 66 Titen® Masonry Screw/Tornillo para mampostería (¹⁄₄" x 2¹⁄₄") For installation in concrete use Titen ¹⁄₄" x 1³⁄₄" Para instalaciones en concreto, utilice Titen de ¹⁄₄" x 1³⁄₄" 16d Sinker (0.
LS LSSU 10dx1½" 1a 1b 1 2 10d x 1¹⁄₂" (0.148" x 1¹⁄₂") 2a 2b 3a 3b 10d (0.148" x 3") 16d (0.162" x 3¹⁄₂") 68 10d (0.
LSTA 1 LTHJR 2³⁄₈" Min. / Mínimo 1 2 10d x 1¹⁄₂" (0.148" x 1¹⁄₂") 10d 3 2 3 Hanger not shown for clarity El soporte colgante no se muestra para ofrecer mayor claridad 10d (0.148" x 3") 10d 10dx1½" 4 5 10d (0.148" x 3") 70 10d x 1¹⁄₂" (0.
LTP4/LTP5 LUCZ Header Joist Viga cabezal Viga 1 10d x 1¹⁄₂" (0.148" x 1¹⁄₂") Fasteners: 2 LTP4 No sheathing: 8dx1 1⁄2" Over sheathing (3⁄8" thick max.): 8d x 2 1⁄2" LTP5 No sheathing: 8dx1 1⁄2" Over sheathing (1⁄2" thick max.): 8d x 21⁄2" Sujetadores: LTP4 Sin relleno: 8dx1 1⁄2" Sobre relleno (3⁄8" de espesor máx.): 8d x 2 1⁄2" 8dx1¹⁄₂" (0.131" x 1¹⁄₂") 16d (0.162" x 3¹⁄₂") LTP5 Sin relleno: 8dx1 1⁄2" Sobre relleno (1⁄2" de espesor máx.): 8d x 2 1⁄2" 3 8d (0.
LUS LUS 1 4 2 5 10d for single 2x 10d para un solo 2x (0.148" x 3") 6 3 74 16d for all others 16d para los demás (0.
MA MAB – Block/Bloque 1 1 10d x 1¹⁄₂" (0.148" x 1¹⁄₂") 10dx1¹⁄₂" (0.
MAB – Concrete/Concreto MAB – Concrete/Concreto 6 1 Concrete MUST cure El concreto DEBE curar 3 2 7 4 5 10d x 1¹⁄₂" (0.
MASA/MAS FORMING ENCOFRADO MASA/MAS CONNECTOR CONECTOR 2-8d Duplex nails / Clavo duplex or/ó 1-10d or/ó 4 1 5 8d Duplex 10dx1¹⁄₂" (0.148" x 1¹⁄₂") Option 1 Opción 1 Reduced loads apply, check with Designer 2 Se aplican cargas reducidas; consulte al diseñador Concrete MUST cure El concreto DEBE curar 10d (0.
MASA/MAS MASA/MAS Brick-Ledge Installation Instalación Sobre Cornisa de Ladrillos Inside-the-Mudsill Installation Instalación en Solera 2-8d Duplex nails / Clavo duplex or/ó 1-10d 2-8d Duplex nails / Clavo duplex or/ó 1-10d 2 1 1 Concrete MUST cure El concreto DEBE curar 2 Concrete MUST cure El concreto DEBE curar 2x4 Plate 3¹⁄₂" MASAP/MASP Similar / Similar 82 83
MST MST 1 2 2a 1a No sheathing / Sin relleno 3 16d (0.162" x 3¹⁄₂") With sheathing / Con relleno END LENGTH LARGO DEL EXTREMO CLEAR SPAN LUZ No nails required here No necesita clavos aquí END LENGTH LARGO DEL EXTREMO 84 3a 16d (0.
PB PHD 1 2 1 2 3 Concrete MUST cure El concreto DEBE curar 16d (0.
PSPN RBC 1 1 2 10d x 1¹⁄₂" (0.148" x 1¹⁄₂") 2 3 3 Up to Hasta 3/4" 16d (0.
RSP4 SB Embedment line (top of concrete) 1 Línea de empotramiento (parte superior del concreto) 1a 8d x 1¹⁄₂" (0.
SP SP4 1 1 10d x 1¹⁄₂" (0.148" x 1¹⁄₂") 2 2 10d (0.
SSP SSTB Embedment line (top of concrete) Línea de empotramiento (parte superior del concreto) 1 24 24 Instalación en solera/similar a la placa inferior 24 Installation on mudsill/ bottom plate similar 10d (0.
STHD – w/StrapMate STC ® 16d Sinker (0.148 " x 3¹⁄₄") 1 SM1 1 Embedment line (top of concrete) Línea de empotramiento (parte superior del concreto) 8d (0.
SUR/L SUR/L 3 1 4 16d 10dx1¹⁄₂" (0.148" x 1¹⁄₂") 10dx1½" 2 16d (0.
THA Installation on Solid Header Instalación Sobre Viga Cabezal Sólida THA Top-Mount Condition / Condición de Montaje Superior 2 1 Installation on Solid Header Instalación Sobre Viga Cabezal Sólida Model Modelo 3 Top & Face Carried Member Encima & Cara Miembro Soportado THA29 THA213 THA413 THA218 16-10d 4-10d 14-10d 4-10d 18-10d 4-10d 22-16d 6-16d 30-16d 6-16d THA218-2 THA418 Install joist nails both sides Instale clavos para vigas a ambos lados THA422 THA222-2 THA422-2 Face Mount Con
THJA THJU 10dx1¹⁄₂" (0.148" x 1¹⁄₂") 10d (0.148" x 3") 1 16d (0.
TSB TSB 1 1 10d x 1¹⁄₂" (0.148" x 1¹⁄₂") 10d x 1¹⁄₂" (0.
Titen HD Titen HD ® ® 1 3 Washer or bearing plate as required by building code Arandela o disco de presión según lo requiera el código de construcción 4 2 1/2" 106 min.
TWB TWB (2) 16d 1 5 2 7 6 8d (0.131" x 2¹⁄₂") at studs / en los montantes 3 16d (0.
VGT VGT 2 SDS ¹⁄₄" x 3" If using an adhesive anchor, see page 24 for instructions. Si utiliza un anclaje adhesivo, consulte las instrucciones de la página 24.
VPA VPA 10d 3 10d 10dx1½" 10dx1¹⁄₂" (0.148" x 1¹⁄₂") 1 4 Required Pitch Inclinación Requerida 10d (0.