Installation Guide

Titen Turbo
Concrete and Masonry Screw Anchor
© 2020 Simpson Strong-Tie Company Inc. F-A-TNT20
7
Easy, fast, reliable — you’ve got to drive it to believe it!
Allowable She
ar Load for Titen Turbo Screw Anchor
Installed in Hollow CMU Wall Faces
1,2,3
Anchor
Diameter
(in.)
Embedment
Depth
(in.)
Minimum Dimensions
Direction of
Loading
Allowable
Load
(lb.)
4
Spacing
(in.)
Edge
(in.)
End
(in.)
3⁄16
1
¼
3
3
3
Toward edge,
parallel to wall end
164
¼
1
¼
4
3
3
Toward edge,
parallel to wall end
190
1. The tabulates values are for screw anchors installed in minimum
8"-wide grouted concrete masonry walls having reached a minimum
f'
m
of 1,500 psi at time of installation.
2. Embedment is the thickness of the face shell.
3. Screw anchors may be installed at any location in the wall face
provided the minimum edge and end distances are maintained.
4. Allowable loads are based on a safety factor of 5.0 for installations
under the IBC and IRC.
Allowable Shear Load for Titen Turbo Screw Anchor
Installed in Face of Grouted CMU
1,2,3
Anchor
Diameter
(in.)
Embedment
Depth
(in.)
Minimum Dimensions
Direction of Loading
Allowable Load
(lb.)
4
Spacing
(in.)
Edge
(in.)
End
(in.)
3⁄16
2 3
3
3
Toward edge, parallel to wall end 218
3⁄16
2 3
1
½
3
Toward wall end, parallel to wall edge 218
¼
2 4
3
3
Toward edge, parallel to wall end 342
¼
2 4
1
½
3
Toward wall end, parallel to wall edge 283
1. The tabulates values are for screw anchors installed in
minimum 8"-wide grouted concrete masonry walls having
reached a minimum f'
m
of 1,500 psi at time of installation.
2. Embedment is measured from the masonry surface to the
embedded end of the screw anchor.
3. Screw anchors must be installed in grouted cell. The
minimum edge and end distances must be maintained.
4. Allowable loads are based on a safety factor of 5.0 for
installations under the IBC and IRC.
Allowable Tension Load for Titen Turbo Screw Anchor
Installed in H
ollow CMU Wall Faces
1,2,3
Anchor
Diameter
(in.)
Embedment
Depth
(in.)
Minimum Dimensions
Allowable
Load
(lb.)
4
Spacing
(in.)
Edge
(in.)
End
(in.)
3⁄16
1
¼
3
3
3
117
¼
1
¼
4
3
3
117
1. The tabulates values are for screw anchors installed in
minimum 8"-wide grouted concrete masonry walls having
reached a minimum f'
m
of 1,500 psi at time of installation.
2. Embedment is the thickness of the face shell.
3. Screw anchors may be installed at any location in the wall face
provided the minimum edge and end distances are maintained.
4. Allowable loads are based on a safety factor of 5.0 for installations
under the IBC and IRC.
Allowable Tension Load for Titen Turbo
Screw Anchor
Installed in Face of Grouted CMU
1,2,3
Anchor
Diameter
(in.)
Embedment
Depth
(in.)
Minimum Dimensions
Allowable Load
(lb.)
4
Spacing
(in.)
Edge
(in.)
End
(in.)
3⁄16
2 3
3
3
267
3⁄16
2 3
1
½
3
267
¼
2
4
3
3
393
¼
2
4
1
½
3
343
1. The tabulates values are for screw anchors installed in minimum 8"-wide
grouted concrete masonry walls having reached a minimum f'
m
of 1,500 psi
at time of installation.
2. Embedment is measured from the masonry surface to the embedded end of
the screw anchor.
3. Screw anchors must be installed in grouted cell. The minimum edge and end
distances must be maintained.
4. Allowable loads are based on a safety factor of 5.0 for installations under the
IBC and IRC.