Installation manual

Cable glands
CABLE GLANDS
The transducer cable must pass t hrough the hull using approved
cable glands for the type of vessel in question.
A steel cable gland is normally used on professional vessels
with steel hulls. A bronze cable gland can be delivered as an
option for vessels with wood or breglass hulls. Vessel not to be
classied can as an option use a cable gland m ade of plastic.
Note
Simrad strongly recommends that a length of conduit is tted
around transducer cable glands made of steel or bronze and
extended over the water-line inside the vessel. This precaution
reduces the danger of ooding in the event of gland failure and
transducers installed in this manner are also easier to replace.
Some vessels may experience difculties nding suitable areas
of the hull for mounting transducer cable glands due to existing
water tanks, concrete ballast or other obstacles. A possible
solution in such cases is to run the transducer cables in a steel
conduit aft along the hull until a suitable cable gland location is
available. The respective cable gland can then be installed as
described in the following instructions.
Note
Simrad takes no responsibility for the correct installation of
cable glands, associated hull modications and/or structural
support of transducer cable penetration. These activities are
subject to individual approval by the respective classication
society for the vessel in question.
Order numbers
The cable glands described in this chapter are available as kits
from Simrad. Observe the following order numbers.
Steel hull cable gland kit (steel): 599-202216
Wood/GRP hull cable gland kit (bronze): 119-038200
Small hull cable gland kit (plastic): 599-202182
305270/A 27