Installation manual

Simrad 50-7
Cable gland for steel hulls
This cable gland kit is designed for steel vessels. It must be
welded to the hull plates.
(CD17008A)
ø35
ø65
A
A
B
C
C
D
E
F
(A) = Steel conduit
(B) = Stufng tube, DNV approved carbon steel st52.3
(C) = Washers, 24 x 8 x 2 mm
(D) = Rubber gasket
(E) = Packing nipple. Make sure that you do not damage the
transducer cable by tightening the packing nipple too hard!
(F) = Cable t o the echo sounder (or a junction box)
The cable gland kit includes all of the necessary parts needed to
install t he unit except screws.
Simrad recommends that a one inch steel conduit (that the
transducer cable will be run through) with an inside threaded
diameter of three-quarter inches is welded to the gland’s stufng
tube. The conduit must extend to above the vessel’s water line.
28