Installation manual

Simrad 50-7
Cable glands for small hulls
This cable glands made of plastic is designed for those smaller
vessels that do not need to be classied.
(CD17008C)
A
A
J
B
C
D
G
E
F
H
I
(A) = Packing nut (bronze). Ensure that you do not to damage
the transducer cable by tightening the packing nut too hard!
(B) = Rubber gasket
(C) = Plastic disk
(D) = Rubber gasket
(E) = Stufng tube
(F) = Backing nut (bronze)
(G) = Backing washer (plastic)
(H) = O-ring 42.5 x 3.0 N
(I) = O-ring 39.5 x 3.0 N
(J) = Cable to the echo sounder (or a junction box)
Stufng tube hole diameter: 36 mm ±1.5 mm.
Apply ample amount of sealant between the backing washer (H)
and the hull plate.
The cable gland kit contains all the listed parts, except the sealant.
Note
The two O-rings must be clean, in
good condition and free of cuts
or other defects which could af
fect their watertight integrity.
30 305270/A