Operation Manual

Installation | 19
LINEAR DRIVE UNITS
MODEL
MOTOR
VOLTS
AUTO-
PILOT
COM-
PUTER
MAX
STROKE
mm (in.)
PEAK
THRUST
kg (lb.)
MAX
RUDDER
TORQUE
Nm (lb.in.)
HARD-OVER
TIME
sec.
(30% load)
PWR.
CON-
SUMP.
TILLER
ARM
mm
(in.)
DD15
12V
AC42
150 Kgm
2 A
HLD350
12V
AC12
200 (7,9)
350
(770)
610
(5400)
12
2,5-8 A
175
(6,9)
HLD2000L
12V
AC42
340 (13,4)
500
(1100)
1460 (12850)
19
3-10 A
298
(11,7)
HLD2000D
24V
AC42
200 (7,9)
1050
(2310)
1800
(15900)
11
3-10 A
175
(6,9)
HLD2000LD
24V
AC42
340 (13,4)
1050
(2310)
3180
(28000)
19
3-10 A
298
(11,7)
MSD50*
12V
AC12
190 (7,5)
60
(132)
15
0,8-2 A
Steering gear interface: Connects to quadrant or tiller.
* For stern drive power assisted steering only.
1. For 12V drive units the motor voltage is stepped
down by the autopilot computer when operating from
24V supply.
2. The specified autopilot computer is necessary to
achieve max drive unit capacity.
3. Recommended operational thrust or torque is 70% of
listed peak value.
4. Typical average power consumption is 40% of listed
maximum value.
Connecting a reversible pump
+
DRIVE
DRIVE
ENGAGE
SOL.-MO
T
OR
SOL.-MO
T
OR
SOL.GND
AC12 Autopilot Computer
SIMRAD Reversible Pump
Figure 2-10 Connecting a reversible pump